MAINTENANCE
CLEANING
Please shut off the unit and unplug from the mains before cleaning or performing any
maintenance
CLEAN THE SURFACE
Clean the plastic housing with a duster or a soft wet cloth.
Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible
damage.
AIR FILTER CLEANING
a) Clean the air filters every 2 weeks. If the air filter is blocked
with dust, the unit’s performance will be significantly affected.
b) Disconnect the power plug from the socket before dismantling,
assembling or cleaning
c) Open the air filter covers and remove the carbon (if installed)
and washable mesh filter
d) Hoover gently the carbon filter and do not wash
e) Wash the mesh air filters by immersing
them in warm (about 40) water with a neutral
detergent.
f) Rinse it and then dry it thoroughly.
g) Carefully re-install air filters back into their cover
Please note: If in use, the optional active carbon filter (cloth)
should be replaced every 3-6 months based on the environment.
END OF SEASON MAINTENANCE
1. Pull out the plug from the drainage hole and empty the internal tank. You can also drain the water
by leaning the unit.
2. Then switch the unit to low fan mode.
3. Keep the unit in this mode for half day - until the conduit is dried. Doing this helps to keep the
inside of the unit dry and prevents mould developing
4. Turn off the unit and pull out the plug.
5. Coil the wire and bind it together, then put it into the accessories space.
6. Separate the air-exhausted pipe and store it safely.
7. Cover the unit and keep it in a dry place.
8. Take the batteries out of remote control and store, or dispose, them safely
Keep all accessories with the unit ready for next season.