Loading ...
Loading ...
Loading ...
The conversion must be performed by a qualified service technician in accordance with
the kit instructions and all local codes and requirements. Failure to follow instructions could
result in serious injury or property damage. The qualified agency performing this work
assumes responsibility for the conversion.
BURNER TYPE
MAX
MIN
LPG
OUTPUT
OUTPUT
Kw
Kw
Nozzle
Cons
Nozzle
Cons
mm
M
3
/h
mm
g/h
Auxiliary Burner
1
0.3
1 x 1.10
0.1
1 x 0.70
73
Semi-Rapid Burners
2
0.55
1 x 1.20
0.19
1 x 0.80
124
Rapid Burner
3 0.8 1 x 1.45 0.29 1 x 0.91 182
Triple Ring Burner
4.5
1.5
5 x Φ0.99
0.43
5 x Φ0.56
327
WARNING
Failure to make the appropriate conversion can result in serious personal injury and property
damage.
TOOLS YOU WILL NEED FOR CONVERSION
Wrench
7mm Nut Driver Safety Glasses
Small Flat-head Screwdriver (2 to 2.4 mm or 3/32 tip size, 60 mm long)
A. ADJUST THE REGULATOR
a) Disconnect all electrical power, at the main circuit breaker or fuse box.
b) Shut off the gas supply to the cooktop by closing the manual shut-off valve.
c) Adjust the pressure regulator by doing the following:
Figure 18