Key
A
B
C
D
E
F
G
H
Function
Switches the blower motor on and off at the last selected
speed
Decreases the vent speed.
Increases the vent speed.
By pressing this key the intensive boost function is activated
from any previously selected speed. The intensive boost can
be activated even when the motor is OFF. After ten minutes of
intensive power, the hood switches back to the last selected
speed. This function is recommended for cooking conditions
where vapors and odors need to be eliminated immediately
and quickly.
By pressing this key the
24 hr - function is set which turns
the hood on at 60 CFM for 10 minutes every hour with a noise
level of just .5 sones. This setting can operate all day and
night to refresh and clean your home. After 10 minutes
every hour, the motor switches off automatically. Press the
button again to turn off the 24 hour function.
When the grease or charcoal filter saturation alarm is triggered
it is possible to reset the alarm by pressing this key for 3 seconds.
The indication is visible only when the motor is off.
By pressing this key the 30 minute delay shutdown mode is
activated which is used to eliminate any residual odor in the
kitchen for 30 minutes. After 30 minutes the hood turns off. It
can be turned on at any speed, and it is turned off by pressing
the key again or by switching off the motor.
Turns light on and off .
Turns the night / comfort light on and off.
Related LED Display Symbol
The current speed is shown when the hood is turned
on.
HI appears. The red dot on the right side flashes
Indicates the
24 hr - function. The red dot on the
right side flashes and the motor is on.
FF Indicates that the metal grease filter
saturation alarm has been triggered, and
the filters need to be washed. The alarm
is triggered after 100 hours of operation
See the next page for instructions on
resetting the alarm
EF Indicates that the charcoal filter
saturation alarm has been triggered, and
the filter has to be replaced; The
charcoal filter is triggered after 200
hours of operation. See the next page for
instructions on resetting the alarm
Indicates both the selected speed of the hood and the
time left before the hood shutdown. The red dot on the
right side flashes alternately displaying the speed and
shutdown time.
USE AND CARE - CONTROL BUTTON FUNCTIONS
The hood can be operated from the control panel located on the
front side of the hood or from the remote control, purchased
seperately.
FIGURE 15 is an illustration of the control panel and FIGURE 16
is the remote control illustration. On the remote control key E and
F are controlled with one button. Press the button once for function
key "F" - 30 minute shut down". Hold for 2 seconds for function key
"E" - 24 hr function.
FIGURE 16
FIGURE 15
LED
A
B
C
D
E/F
H
G