Loading ...
Loading ...
Loading ...
10
/ Gas
PRECAUTIONS WHEN USING THE PRODUCT
WITH LPG (BUTANE/PROPANE)
The gas taps installed on the hob must operate
with liquefi ed gas of controlled quality, supplied at
the correct nominal pressure.
This pressure must be guaranteed by a certifi ed
dedicated pressure regulator (not supplied with
the product).
The use of gas from uncertifi ed refi lls and/
or improper use of LPG cylinders, as well as
the corresponding regulator, can invalidate the
product warranty.
In particular, you must avoid all situations where
the gas could be polluted with residues and
impurities which, when they enter the gas circuit,
could
irreparably damage the control components such
as the taps and thermostats.
We therefore recommend:
Using only LPG cylinders from offi cial resellers
authorised by the various manufacturers
Using the cylinders until they are empty but
without tilting or overturning them
Regularly cleaning the lter at the inlet to the
pressure regulator
Burner Gas type Pressure Nozzle
diameter
Hourly Gas
Consumption
kPa mm MJ
Auxiliary
NG 1,0 0,92 3,6
U LPG 2,75 0,56 3,6
Semi-rapid
NG 1,0 1,17 6,9
U LPG 2,75 0,73 6,3
Rapid
NG 1,0 1,55 10,8
U LPG 2,75 0,98 10,8
Wok
NG 1,0 1,80 14,4
U LPG 2,75
0,98 12,8
Dual wok
NG 1,0
ext 2x110
14,8
int 80
U LPG 2,75
ext 2x65
14,8
int 50
Regulating the appliance for various gas types