Esatto EPAC29C 2.9kW Air Conditioner

User Manual - Page 7

For EPAC29C. Also, The document are for others Esatto models: EPAC38C

PDF File Manual, 13 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
User Manual esatto.house 12 13
Operation Instructions (Continued)
WIRELESS BUTTON MAY NOT BE APPLICABLE
Used to initiate the wireless connection mode. For the
rst time to use wireless function, press the wireless
button for 3 seconds to initiate the wireless connection
mode. The LED DISPLAY shows ‘AP’ to indicate you
can set wireless connection. If connection(router) is
successful within 8 minutes, the unit will exit wireless
connection mode automatically and the wireless
indicator illuminates. If connection is failure within
8 minutes, the unit exits wireless connection mode
automatically. After Wireless connection is successful,
for some models you can press Wireless and DOWN
(-) buttons at the same time for 0.5 seconds to turn
o Wireless function and the LED DISPLAY shows
‘OF’ for 3 seconds, press Wireless button to turn on
Wireless function and the LED DISPLAY shows ‘ON’ for
3 seconds.
NOTE: When you restart the wireless function, it
may take a period of time to connect to the network
automatically.
SWING BUTTON MAY NOT BE APPLICABLE
Used to initiate the Auto swing feature. When the
operation is ON, press the SWING button can stop the
louver at the desired angle.
SLEEPECO/FILTER BUTTON
Used to initiate the SLEEP/ECO operation.
NOTE: After 250 hours of operation, the lter indicator
light illuminates. This feature is a reminder to clean the
Air Filter for more ecient operation. Press this button
for 3 seconds to cancel the reminder.
TIMER BUTTON
Used to initiate the AUTO ON start time and AUTO OFF
stop time program, in conjuction with the Up & Down
buttons. The timer on/o indicator light illuminates
under the timer on/o settings.
FAN/ION BUTTON ION MAY NOT BE APPLICABLE
Control the fan speed. Press to select the fan speed in
four steps-LOW, MID(MED), HIGH and AUTO. The fan
speed indicator light illuminates under dierent fan
settings.
NOTE: Press this button for 3 seconds to initiate ION
feature. The ION light illuminates. The ion generator is
energized and will help to remove pollen and impurities
from the air, and trap them in the lter. Press it for
3 seconds again to stop the ION feature.
MODE BUTTON
Selects the appropriate operating mode. Each time
you press the button, a mode is selected in a sequence
that goes from AUTO, COOL, DRY, FAN and HEAT
(cooling only models without). The mode indicator light
illuminates under the dierent mode settings.
UP AND DOWN BUTTONS
Used to adjust (increasing/decreasing) temperature
settings in 1°C/1°F (or 2°F) increments in a range of
17°C/62°F to 30°C/86°F (or 88°F) or the TIMER setting in
a range of 0~24hrs.
NOTE: The control is capable of displaying temperature
in degrees Fahrenheit or degrees Celsius. To convert
from one to the other, press and hold the Up and Down
buttons at the same time for 3 seconds.
POWER BUTTON
Power switch on/o.
LED DISPLAY
Shows the set temperature in °C or °F and the
Auto-timer settings. While on DRY and FAN modes, it
shows the room temperature.
Shows Error codes and protection code:
E1 - Room temperature sensor error.
E2 - Evaporator temperature sensor error.
E3 - Condenser temperature sensor error
(on some models).
E4 - Display panel communication error.
EC - Refrigerant leakage detection malfunction
(on some models).
E7 - Zero-crossing malfunction.
P1 - Bottom tray is full—Connect the drain hose and
drain the collected water away. If protection
repeats, call for service.
NOTE: When one of the above malfunctions occurs,
turn o the unit, and check for any obstructions.
Restart the unit, if the malfunction is still present, turn
o the unit and unplug the power cord. Contact the
manufacturer or its service agents or a similar qualied
person for service.
COOL OPERATION
Pressi the “MODE” button until the “COOL” ndicator
light comes on.
Press the ADJUST buttons “+” or “-” to select your
desired room temperature. The temperature can be
set within a range of 17°C~30°C/62°F~88°F
(or 86°F).
Press the “FAN SPEED” button to choose the
fanspeed.
HEAT OPERATION MAY NOT BE APPLICABLE
Press the “FAN SPEED” button to choose the fanspeed.
Press the “MODE” button until the “HEAT” indicator
light comes on.
Press the ADJUST buttons “+” or “-” to select your
desired room temperature. The temperature can be
set within a range of 17°C~30°C/62°F~88°F(or 86°F).
Press the “FAN SPEED” button to choose the fan speed.
For some models, the fan speed can not be adjusted
under HEAT mode.
DRY OPERATION
Press the “MODE” button until the “DRY” indicator
light comes on.
Under this mode, you cannot select a fan speed or
adjust the temperature. The fan motor operates at
LOW speed.
Keep windows and doors closed for the best
dehumidifying eect.
Do not put the duct to window.
AUTO OPERATION
When you set the air conditioner in AUTO mode, it
will automatically select cooling, heating(cooling
only models without), or fan only operation
depending on what temperature you have selected
and the room temperature.
The air conditioner will control room temperature
automatically round the temperature point set by you.
Under AUTO mode, you can not select the fan speed.
NOTE: Under AUTO mode, both the AUTO mode
and the actual operation mode indicator light (A)
illuminate for some models.
FAN OPERATION
Press the “MODE” button until the”FAN “ indicator
light comes on.
Press the “FAN SPEED” button to choose the fan
speed. The temperature can not be adjusted.
Do not put the duct to window.
TIMER OPERATION
When the unit is on, press the Timer button will
initiate the Auto-o stop program, the TIMER OFF
indicator light illuminates. Press the UP or down
button to select the desired time. Press the TIMER
button again within 5 seconds, the Auto-on start
program is initiated. And the TIMER ON indicator
light illuminates. Press the up or down button to
select the desired Auto-on start time.
When the unit is o, press the Timer button to initiate
the Auto-on start program, press it again within ve
seconds will initiate the Auto-o stop program.
Press or hold the UP or DOWN button to change the
Auto time by 0.5 hour increments, up to 10 hours,
then at 1 hour increments up to 24 hours. The control
will count down the time remaining until start.
The system will automatically revert back to display
the previous temperature setting if there is no
operation in a 5 seconds period.
Turning the unit ON or OFF at any time or adjusting
the timer setting to 0.0 will cancel the Auto Start/
Stop timer program.
When the malfunction occurs, the Auto Start/Stop
timed program will also be cancelled.
SLEEP/ECO OPERATION
Press this button, the selected temperature will
increase (cooling) or decrease(heating) by 1°C/2°F
(or 1°F) 30 minutes. The temperature will then
increase (cooling) or decrease (heating) by another
1°C/2°F (or 1°F) after an additional 30 minutes. This
new temperature will be maintained for 7 hours before
it returns to the originally selected temperature. This
ends the Sleep/Eco mode and the unit will continue to
operate as originally programmed.
NOTE: This feature is unavailabe under FAN or DRY mode.
Loading ...
Loading ...
Loading ...