Loading ...
Loading ...
Loading ...
Safety distances
44
Safety distances to the sides
and back of the appliance
Ideally the cooktop should be installed
with plenty of space on either side.
There may be a wall at the rear or a tall
unit or wall on one side (right or left),
taking into account the distances
below. On the other side, however, no
tall unit or wall should stand closer than
300mm to the edge of the cooktop.
Before installing the cooktop, check
that the below clearance requirements
are met.
Minimum horizontal distance from the
back edge of the cooktop to a
combustible surface:
50mm.
Minimum horizontal distance from the
right edge of the cooktop to a
combustible surface:
50mm.
Minimum horizontal distance from the
left edge of the cooktop to a
combustible surface:
50mm.
Minimum safety distances
underneath the cooktop
To ensure sufficient ventilation to the
cooktop, a certain gap must be left
between the underside of the cooktop
and any oven, interim shelf or drawer.
The minimum gap between the
underside of the cooktop and
the top of an oven is 15mm.
the top of an interim shelf is 15mm.
the base of a drawer is 75mm.
Interim shelf
It is not necessary to fit an interim shelf
underneath the cooktop but one may
be fitted if you wish.
Leave a gap of 10mm at the back of
the shelf to accommodate the cable.
Miele recommends a gap at the front of
the shelf of 20mm to ensure good
ventilation.
Loading ...
Loading ...
Loading ...