13
OPERATING YOUR HEATER
ML100TBAHR
THERMOSTAT MODEL
FOR YOUR SAFETY
READ BEFORE LIGHTING
A. When lighting the pilot, follow these
instructions exactly.
B. BEFORE LIGHTING smell all
around the appliance area for gas.
Be sure to smell next to the oor
because some gas is heavier than
air and will settle on the oor.
Figure 19 - Control Knob In The
OFF Position
Figure 20 - Pilot
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric
switch, do not use any phone
in your building.
Immediately call your gas
suppl ier from a nei gh-
bors phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas
supplier, call the re department.
C. Use only your hand to push in
or turn the gas control knob. Never
use tools. If the knob will not push
in or turn by hand, don’t try to repair
it , call a qualied service technician
or gas supplier. Force or attempted
repair may result in a re or explosion.
D. Do not use this appliance if
any part has been under water.
Immediately call a qualied service
technician to inspect the appliance
and to replace any part of the control
system and any gas control which
has been under water.
WARNING: If you do not fol-
low these instructions exactly, a re
or explosion may result causing
property damage, personal injury or
loss of life.
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety
information on the side of heater.
2. Make sure equipment shutoff
valve is fully open.
3. Turn control knob clockwise
to the OFF position.
4. Wait ve(5) minutes to clear
out any gas. Then smell for gas,
including near the oor. If you
smell gas, STOP! Follow B in the
safety information on the side of
heater. If you don’t smell gas,
go to the next step.
5. Turn control knob counterclock-
wise to the PILOT position.
Press in control knob for ve(5)
seconds. (see Figure 19).
Note: You may be running this
heater for the rst time after
hooking up to gas supply. If so,
the control knob may need to be
pressed in for 30 seconds. This
will allow air to bleed from the
gas system.
If control knob does not pop
up when released, contact a
qualied service person or gas
supplier for repairs.
6. With control knob pressed in,
push down and release ignitor
button. This will light pilot. The
pilot is attached to the front of
burner. If needed, keep pressing
ignitor button until pilot lights.
Note: If pilot does not stay lit, refer
to Troubleshooting, pages 15
through 17. Also contact a qual-
ified service person or gas
supplier for repairs. Until re-
pairs are made, light pilot with
match.To light pilot with match,
see Manual Lighting Procedure.
7. Keep control knob pressed in for
30 seconds after lighting pilot.After
30 seconds, release control knob.
If control knob does not
pop up when released, contact a
qualied service person or gas
supplier for repairs.
Note: If pilot goes out,repeat steps 3
through 7.This heater has a safety
interlock system. Wait one(1)
minute before lighting pilot again.
8. Turn control knob counter clock-
wise to desired seating
level. The main burner should
light. Set control knob to any
heat level between HI and LO
(5-1).
THERMOSTAT CONTROL OPERATION
The thermostatic control used on this
model differs from standard
thermostats. Standard thermostats
simply turn on and off the burner. The
thermostat used on this heater senses
the room temperature. At times the
room may exceed the set temperature.
If so,the burner will shut off. The burner
will cycle back on when room tempera-
ture drops below the set temperature.
The control knob can be set t o any
comfort level between HI and Low (5-1).
Note: The thermostat sensing bulb
measures the temperature of air near
the heater cabinet.This may not always
agree with room temperatur(depending
on housing construction, installation
location, room size, open air
temperatres,etc.) Frequent use of your
heater will let you determine your own
comfort levels.
TO TURN OFF
GAS TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
to the OFF position.
2. Turn off all electric power to the
appliance if service is to
be performed.
Shutting Off Burner Only (pilot
stays lit )
Turn control knob clockwise to
the PILOT position.
CAUTION: Do not try to
adjust heating levels by using the
equipment shutoff valve.
Loading ...
Loading ...