Figure 18 - Pilot
ML100HBAHR
Manual Control Models
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety
information on the side of
heater.
2. Check that gas supply to
heater is on.
3. Push in gas control knob
slightly and turn clockwise
to the OFF position.
4. Wait ve (5) minutes to clear
out any air. Then smell for
gas, including near the oor.
If you smell gas, STOP!
Follow “B” in the safety
information on the side of the
heater. If you do not smell
gas, go to the next step.
5. P u s h i n g a s c o n t rol kn o b
slightly and turn counter-
clockwise to“PILOT/IGN”
and depress for ve (5) seconds
NOTE: The rst time that the
heater is operated after connect-
ing the gas supply , the control
knob should be depressed for
about thirty (30) seconds. This will
allow air to bleed from the gas
system.
6. With control knob pressed in,
push down and release the
ignitor button. This will light
pilot. If needed, keep pressing
ignitor button until pilot lights.
7. Keep control knob depressed
for ten (10) seconds after
lighting pilot. If pilot goes out,
repeat steps 5,6 and 7.
8. To select the desired heating
level, partially press down the
control knob slightly and rotate
counterclockwise . Release the
downward pressure on the knob
while continuing to turn until the
knob locks at the desired setting
po s it i on . Do n ot o p er a te
between locked positions.
TO TURN OFF
GAS TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
to the OFF position.
2. Turn off all electric power to
the appliance if service is to
be performed.
Shutting Off Burner Only (Pilot
Stays Lit)
Turn control knob clockwise
to the PILOT/IGN position.
MANUAL LIGHTING
PROCEDURE
1. Remove lower front panel (see
Figure 7 page 7)
2. Follow steps 1 through 5
under Lighting Instructions.
3. With control knob pressed in,
strike match. Hold match to
pilot until pilot lights.
4. Keep control knob pressed in
for 30 seconds after lighting
pilot. After 30 seconds, release
control knob.Follow step 8
under Lighting Instructions.
5. Replace lower front panel.
OPERATING YOUR HEATER
Figure 17 - Control Knob In The
OFF Position
Set control knob to desired
heating position.
NOTE: Both HIGH and LOW are
locked positions. You must press
in control knob before turning it
from these positions.
WARNING: If you do not follow
these instructions exactly, a re
or explosion may result causing
property damage, personal injury
or loss of life.
CAUTION: Do not try to adjust
heating levels by using the
equipment shutoff valve.