Loading ...
Loading ...
Loading ...
31-2000734 Rev. 0 11
Installation
1
INSTALL HOOD SUPPORT
IMPORTANT: Framing must be capable of supporting
100 lbs for 36” models and 150 lbs for 48” models.
Locate a minimum of 2 vertical studs for the
installation bar by tapping drywall with a hammer or
use a stud finder.
Level the installation bar and center left to right
above the marked line. Hold bar against the wall.
Drill 1/8” pilot holes at the 2 vertical stud locations
through holes in the installation bracket. Secure the
installation bar with supplied screws (A) as shown
above.
Drill Bottom Mounting Hole Locations:
Hang hood on installation bar or use the table below
to mark the screw hole locations. NOTE: If installing
to the soffit, push hood flush to the soffit before
marking screw hole locations.
Remove the hood and drill 5/16” clearance holes at
marked locations “A” and “B”.
2
INSTALL DAMPER
IMPORTANT: Remove shipping tape from damper
and check that damper moves freely.
Install Top Damper:
The motor mounting plate comes pre-installed in the
hood for top venting.
Install the top damper to the hood body as shown in
Figure A using screws (B) from top of hood.
Install Back Damper:
In case of back venting through the wall, back
damper accessory UXBDA812 must be purchased
separately.
Uninstall the motor mounting plate from top venting
position. Save the screws.
Remove the square knockout panel on hood body for
back venting.
Remove the two screw knockout holes on the motor
mounting plate as shown in Figure C.
Install the motor mounting plate to back panel so that
the arrow on plate is pointing upwards and on the
right side.
Push plate in until metal clips
engage. Fasten plate through
screw knockouts shown in
Figure C using the two screws
saved.
Install the back damper to the
hood body as shown in Figure
B using screws provided with
the accessory.
Install the metal plate provided with the accessory to
cover the opening for top damper.
Installation Bar
Centerline of
Installation Space
16-3/4”
24” minimum over electric range
or cooktop, or 30” minimum over
gas range or cooktop, and 36”
recommended maximum.
Figure A
Figure B
1
INSTALL HOOD SUPPORT (Cont.)
Install wall anchors (C) by tapping the anchors with
a hammer to seat the teeth of the flanges into the
wall. This keeps anchor from rotating.
Drive the anchor screws until the barrels crimp
against the inside of the wall.
Remove the screws from the wall anchors before
installing the hood.
B
A
Bottom of Hood
Centerline of
Installation Space
“A” “B”
36” Model 11-7/8”
4”
48” Model 17-3/4”
TOP
Figure C (Panel will look
different for single motor)
Screw Knockouts
Loading ...
Loading ...
Loading ...