10 31-2000734 Rev. 0
Installation Preparation
DETERMINE HOOD, DUCTWORK AND WIRING LOCATIONS
This hood can be installed onto the wall or underneath
the soffit.
For installing the hood to soffit, refer to page 12 for
alternate mounting method.
A wall mounting template is included with the product
for ease of installation. Follow the instructions below if
the template is not being used.
Measure desired distance from the bottom of the hood
to the cooking surface, 24” minimum over electric range
or 30” minimum over gas range and 36” recommended
maximum.
Use a level to draw the cooktop centerline location.
Measure 16-3/4” up from the horizontal line indicating
the bottom of the hood. Draw another horizontal line to
indicate the bottom of the installation bar.
Use a level to draw the cooktop or range centeline
location.
For Ceiling Ducting:
If venting out the ceiling, extend the centerline forward
on the ceiling to the back wall.
- Measure 6-1/4” from back wall to mark center point.
- Cut 10” dia. duct hole from center point on the
ceiling.
Venting Through a Soffit:
Follow the same procedure for ceiling ducting to cut
the hole through the top of the soffit.
For Ducting Through Rear Wall:
NOTE: Check to make sure back damper will not
interfere with studs, electrical or plumbing before making
cut out.
Back damper accessory UXBDA812 must be
purchased separately for venting through the rear wall.
Measure 5-7/8” up along the centerline from the
horizontal line indicating bottom of the hood.
Make an 10-1/2”x13-1/4” cut out centered left to right
along the centerline.
House Wiring Location:
The junction box is located inside the hood body on the
left side. See Illustrations for hood knockout locations.
House wiring may enter the junction box from the rear or
the top of the hood on the left side.
To route house wiring through the ceiling or soffit:
Cut a hole approximately 1-1/4” dia. forward on the
ceiling 10-1/4” to the left of the centerline.
To route house wiring through the wall:
NOTE: For back venting, the house wiring must be
routed through the rear knockout so it is hidden.
Measure 15-3/4” from the bottom of the hood and mark
location
Cut a hole approximately 1-1/4” dia. at the marked
location at a distance 10-1/4” to the left of the
centerline based on table below.
Remove top or rear knockout depending on your
installation.
Centerline to Wall
FOR CEILING VENT
DUCTING
Duct Hole
Top of Hood
Installation
Bar
Bottom of Hood
FOR REAR WALL DUCTING
6-5/8”
5-7/8”
10-1/2”
16-3/4”
1-1/4”
Top View
Rear View
10-1/4”
10-1/4”
15-3/4”