User Manual 43072 GE - General Electric Networking

Documents for GE - General Electric 43072

The following documents are available:
User Manual Other Documents
  • Specification Sheet - (English) Download
Photos
43072 photo
Out to Light (Load)
C
A
D
B
E
From Breaker Box
C
E
D
A
B
OR
OR
Multi-switch wiring
For 3-way installations, please refer to GE-branded Add-on Switch manual
Single-switch wiring
Before installation, you may wish to change the paddle color to match
your wallplate or decor. Please proceed to section 5.
1. Shut off power to the circuit at circuit breaker or fuse box.
IMPORTANT! Verify power is OFF to switch box before continuing.
2. Remove wallplate.
3. Remove the switch mounting screws.
4. Carefully remove the switch from the switch box. DO NOT disconnect the wires.
5. There are up to five screw terminals on the switch; these are marked:
A. GROUND — Green/Bare
B. LINE OR LOAD — Black (connected to power or lighting)
C. LINE OR LOAD — Black (connected to power or lighting)
D. TRAVELER — Red/Other (only in 3-way installations)
E. NEUTRAL — White
Match these screw terminals to the wires connected to the existing switch.
6. Disconnect the wires from the existing switch. Label wires
according to the previous terminal connection.
Observe important wiring information
IMPORTANT! This switch is rated for and intended to only be used with copper wire.
Wire gauge requirements
Use 14AWG or larger wires suitable for at least 80° C for supplying
line (hot), load, neutral, ground and traveler connections.
Wire strip length:
1. For attachment using the enclosure’s holes, strip insulation 5/8in. (16mm).
UL specifies that the tightening torque for the screws is 14Kgf-cm (12lbf-in).
2. Connect the green or bare copper ground wire to the GROUND terminal.
3. Connect the black wire from the light to either LINE/LOAD terminal.
4. Connect the black wire from the electrical service panel (hot) to either LINE/LOAD terminal.
5. Connect the white wire to the NEUTRAL terminal (use a jumper wire if needed).
Note:
The traveler terminal is only used for 3-way or 4-way wiring and should remain
insulated if the switch is being installed in a 2-way system (one switch & one load).
6. Insert switch into the switch box being careful not to pinch or crush wires.
7. Switch must be independently mounted (vertical position only).
8. Secure the switch to the box using the supplied screws.
9. Mount the wallplate.
10. Reapply power to the circuit at fuse box or circuit breaker and test the system.
Basic operation
The connected light can be turned ON/OFF in two ways:
1. Manually from the front panel of the switch.
2. Remotely with a Z-Wave controller.
Manual control
The front panel rocker switch allows the user to, turn ON/OFF the connected fixture.
1. To turn the connected fixture ON, press and release the top of the rocker.
2. To turn the connected fixture OFF, press and release the bottom of the rocker.
Cycle LED light
The LED below the switch acts as a guide light or status indicator.
How to cycle through options: Press up three times and down once quickly.
1. LED is ON when the load is off (guide light in the dark) (default)
2. LED is ON when the load is ON (indicates the switch is ON)
3. LED is always OFF
4. LED is always ON (illuminates switch in the dark)
A. Ground (Green/Bare)
B. Line or Load (Black)
C. Line or Load (Black)
D. Traveler (Red/Other)
E. Neutral (White)
F. Top rocker — Press & release
to turn switch ON
G. Bottom rocker — Press &
release to turn switch OFF
Getting to know your new Z-Wave device
Turn ON/OFF manually or remotely via the Z-Wave controller
Can be added in multiple groups and scenes
May be used in single pole installation or with up to four GE-branded
Add-on Switches in 3-way or 4-way wiring configurations
Compatible with all incandescent and CFL/LED bulbs
Auto line/load detection
Interchangeable paddle switch — white & light almond paddle in package
Uses a standard, decorative-size wallplate for single-gang installations
(wallplate not included)
Blue LED indicates switch location in a dark room
Z-Wave certified for simple pairing and integrated home automation
Screw terminal installation — requires wiring connections for line (hot), load,
neutral and ground. Traveler wire required for 3-way or 4-way installation
This Z-Wave device has advanced features that allow you to customize
your experience. These features can only be adjusted by a Z-Wave enabled
controller that supports the Z-Wave configuration command class. For a
complete list of adjustable configurations, visit www.ezzwave.com/config
WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the switch and lighting fixture at the service
panel. All wiring connections must be made with the POWER OFF to avoid personal injury
and/or damage to the switch. This device is intended for installation in accordance with the
National Electric Code and local regulations in the United States or the Canadian Electrical
Code and local regulations in Canada. If you are unsure or uncomfortable about performing
this installation consult a qualified electrician.
3.
2.
G
F
From Breaker Box
Out to Light (Load)
Fr
Cet appareil est conforme au paragraphe 15 des normes FCC et au CNR pour les appareils exempts de
licence d’Industrie Canada. Son utilisation est sujette aux deux conditions suivantes : 1 cet appareil ne
doit pas occasionner de brouillage préjudiciable et 2 cet appareil doit accepter toutes les interférences
reçues, notamment les interférences qui peuvent provoquer un fonctionnement non désiré.
NOTE DE LA FCC : Le fabricant n’est pas responsable des interférences sur les fréquences
radioélectriques ou télévisuelles pouvant être causées par des modifications non autorisées de ce
matériel. De telles modifications peuvent annuler le droit de l’utilisateur à utiliser cet appareil.
REMARQUE : Cet appareil a été testé et certifié conforme aux limites relatives aux appareils
numériques de catégorie B définies dans le paragraphe 15 des normes FCC. Ces limites ont été définies
afin de fournir une protection raisonnable contre le brouillage préjudiciable en milieu résidentiel. Cet
appareil produit, utilise et peut émettre des ondes de fréquence radio et, s’il n’est pas installé et utilisé
conformément aux instructions, il peut provoquer un brouillage préjudiciable aux communications
radio. Il n’existe toutefois aucune garantie que des interférences ne se produiront pas au sein d’une
installation donnée. Si cet appareil occasionne un brouillage préjudiciable à la réception radiophonique
ou télévisuelle, il suffit d’allumer et d’éteindre l’appareil pour déterminer sa responsabilité. Nous
encourageons l’utilisateur à essayer de corriger ces interférences en appliquant une ou plusieurs des
mesures suivantes :
— Réorienter ou déplacer l’antenne de réception.
— Augmenter la distance entre l’appareil et le récepteur.
— Brancher l’appareil à une prise secteur différente de celle du récepteur.
— Consulter le revendeur ou un technicien spécialisé en postes radio ou téléviseurs.
Remarque importante : Pour se conformer aux exigences de conformité de la FCC concernant
l’exposition aux RF, aucune modification apportée à l’antenne ou au dispositif n’est autorisée. Toute
modification apportée à l’antenne ou au dispositif pourrait faire en sorte que le dispositif dépasse les
exigences d’exposition aux RF et pourrait annuler le droit de l’utilisateur à utiliser ce dispositif.
En
This device complies with Part 15 of the FCC and Industry Canada license-exempt RSS standards.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy, and if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from which the
receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
Important note: To comply with the FCC RF exposure compliance requirements, no change to the
antenna or the device is permitted. Any change to the antenna or the device could result in the device
exceeding the RF exposure requirements and void user’s authority to operate the device.
Es
Este dispositivo cumple con las Especificaciones del apartado 15 de las normas de la FCC y con las
especificaciones de las normas radioeléctricas (RSS) del Ministerio de Industria de Canadá aplicables
a aparatos exentos de licencia. El funcionamiento está sujeto a las siguientes dos condiciones:
(1) este dispositivo no debe provocar interferencia perjudicial, y (2) este dispositivo debe aceptar
toda interferencia que reciba, incluso la que pudiera causar un funcionamiento no deseado.
NOTA DE LA FCC: El fabricante no se hace responsable de ninguna interferencia de radio
o TV ocasionada por modificaciones no autorizadas efectuadas a este equipo. Dichas
modificaciones podrían anular la autoridad del usuario para utilizar el equipo.
NOTA: Este equipo ha sido probado y cumple con los límites para aparatos digitales de Clase B,
de conformidad con el apartado 15 de las normas de la FCC. Estos límites están diseñados para
proveer protección razonable contra interferencias perjudiciales en una instalación residencial. Este
equipo genera, usa y puede irradiar energía de radiofrecuencias y, si no se instala y usa según las
instrucciones, puede provocar interferencia perjudicial a las radiocomunicaciones. No obstante, no
hay garantías de que no ocurrirá interferencia en una instalación en particular. Si este equipo provoca
interferencia perjudicial a la recepción de radio o televisión, lo que puede determinarse encendiendo y
apagando el equipo, se recomienda que el usuario intente corregir la
interferencia por medio de la implementación de una o más de las siguientes medidas:
Reorientar o reubicar la antena receptora.
Incrementar la separación entre el equipo y el receptor.
Conectar el equipo a un tomacorriente de un circuito diferente
del circuito al que está conectado el receptor.
Consultar al distribuidor o a un técnico con experiencia en radio/televisión para
solicitar asistencia.
Nota importante: Para cumplir con los requisitos de cumplimiento de exposición de
radiofrecuencia de la FCC, no se permiten cambios a la antena o el dispositivo. Cualquier
cambio a la antena o dispositivo podría hacer que el dispositivo supere los requerimientos de
exposición de radiofrecuencia y anular la autoridad del usuario para operar el dispositivo.
Responsible Party - US Contact Information | Parte responsable - Información de contacto de los
Estados Unidos | Partie responsable - Coordonnées des États-Unis
ZW4008:
FCC — U2ZZW4008 | IC: 6924A-ZW4008
ZW4008DV:
FCC — U2ZZW4008DV | IC: 6924A-ZW4008DV
Jasco Products Company | Model: ZW4008/46201/ZW4008DV/43072
10 E. Memorial Rd., Oklahoma City, OK 73114 | 1-800-654-8483
CAN ICES-3(B)/NMB-3(B)
All brand names shown are trademarks
of their respective owners.
Tous les noms de marque illustrés sont des marques
de commerce de leurs propriétaires respectifs.
Todas las marcas que aparecen aquí son marcas
registradas de sus respectivos dueños.
MADE IN CHINA/FABRIQUÉ EN CHINE/HECHO EN CHINA
GE IS A TRADEMARK OF GENERAL ELECTRIC COMPANY AND
IS UNDER LICENSE BY JASCO PRODUCTS COMPANY LLC,
10 E. MEMORIAL RD., OKLAHOMA CITY, OK 73114.
©JASCO 2019 | 46201 | ZW4008 | 43072 | ZW4008DV 4/18/19 v2
FCC / IC
If you have any problems or questions, contact our U.S.-based Consumer Care at
1-800-654-8483, option 1, Monday–Friday, 7AM–8PM CST.
For the most up-to-date product support, accessories, electronic (PDF)
format manuals and more, visit www.byjasco.com/support.
• No user serviceable parts in this unit.
Si vous avez des problèmes ou des questions, veuillez communiquer avec notre
service à la clientèle aux États-Unis au 1-800-654-8483, option 1, du lundi au
vendredi, de 7 h à 20 h (HNC).
Pour le soutien relatif aux produits le plus à jour, les accessoires, les manuels en
format électronique (PDF) et plus encore, visitez le site www.byjasco.com/support.
• Aucune des pièces de ce dispositif ne peut être réparée par l’utilisateur.
Si tiene problemas o dudas, comuníquese con nuestro Centro de
atención al cliente con sede en EE. UU. al 1-800-654-8483, opción 1 de
lunes a viernes, de 7 a.m. a 8 p.m., hora estándar del centro (CST).
Para recibir el soporte técnico más actualizado sobre productos, accesorios,
manuales en formato digital (PDF), entre otros, visite www.byjasco.com/support.
• Esta unidad no contiene piezas que el usuario pueda reparar.
DO NOT RETURN THIS
PRODUCT TO THE STORE
NE RETOURNEZ PAS
CE PRODUIT AU MAGASIN
NO DEVUELVA ESTE
PRODUCTO A LA TIENDA
STOP
RIESGO DE INCENDIO
RIESGO DE DESCARGA ELÉCTRICA
RIESGO DE QUEMADURAS
CONTROL DE EQUIPOS ELECTRODOMÉSTICOS
PRECAUCIÓN:
USAR EXCLUSIVAMENTE PARA
CONTROLAR BOMBILLAS CFL/LED
INCANDESCENTES O ATENUABLES
NO SUPERE LOS VALORES NOMINALES ELÉCTRICOS
NO USAR PARA CONTROLAR DISPOSITIVOS
EN LOS QUE EL FUNCIONAMIENTO NO
INTENCIONADO PODRÍA PROVOCAR
SITUACIONES PELIGROSAS (LÁMPARAS DE
CALEFACCIÓN, LÁMPARAS SOLARES, ETC.)
NO UTILICE PARA CONTROLAR TOMACORRIENTES
USE SOLAMENTE EN INTERIORES
RISK OF FIRE
RISK OF ELECTRICAL SHOCK
RISK OF BURNS
CONTROLLING APPLIANCES
CAUTION:
DO NOT EXCEED RATINGS
DO NOT USE TO CONTROL ANY DEVICE WHERE
UNINTENDED OPERATION COULD CAUSE UNSAFE
CONDITIONS (HEAT LAMP, SUN LAMP, ETC.)
DO NOT USE TO CONTROL RECEPTACLES
FOR INDOOR USE ONLY
RISQUE D’INCENDIE
RISQUE DE CHOC ÉLECTRIQUE
RISQUE DE BRÛLURES
COMMANDE DES APPAREILS
ATTENTION:
UTILISER SEULEMENT POUR COMMANDER
LES AMPOULES À DEL ET FLUOCOMPACTES À
INCANDESCENCE OU À INTENSITÉ RÉGLABLE
NE PAS DÉPASSER LES
CARACTÉRISTIQUES NOMINALES
NE PAS UTILISER POUR COMMANDER DES
APPAREILS POUR LESQUELS UN FONCTIONNEMENT
IMPRÉVU POURRAIT ENTRAÎNER DES
CONDITIONS DANGEREUSES (LAMPE À RAYONS
INFRAROUGES, LAMPE SOLAIRE, ETC.)
NE PAS UTILISER POUR COMMANDER
LES PRISES DE COURANT
POUR UTILISATION INTÉRIEURE UNIQUEMENT
AVERTISSEMENT
WARNING ADVERTENCIA
NOT FOR USE WITH MEDICAL OR
LIFE-SUPPORT EQUIPMENT
Z-WAVE ENABLED DEVICES SHOULD NEVER BE USED
TO SUPPLY POWER TO OR CONTROL THE ON/OFF
STATUS OF MEDICAL OR LIFE-SUPPORT EQUIPMENT.
NE PAS UTILISER AVEC UN ÉQUIPEMENT
MÉDICAL OU DE SURVIE
LES DISPOSITIFS COMPATIBLES AVEC LA TECHNOLOGIE
Z-WAVE NE DEVRAIENT JAMAIS ÊTRE UTILISÉS POUR
ALIMENTER OU COMMANDER LA MISE EN MARCHE OU
L’ARRÊT DE L’ÉQUIPEMENT MÉDICAL OU DE SURVIE.
SE PROHÍBE SU EMPLEO EN EQUIPO MÉDICO
O EQUIPO PARA EL MANTENIMIENTO
DE LAS FUNCIONES VITALES
LOS DISPOSITIVOS Z-WAVE NUNCA SE DEBEN USAR
PARA SUMINISTRAR ENERGÍA ELÉCTRICA AL EQUIPO
MÉDICO O AL EQUIPO PARA EL MANTENIMIENTO DE
FUNCIONES VITALES, NI PARA CONTROLAR EL ESTADO
DE ENCENDIDO O APAGADO DE DICHOS EQUIPOS.
Tools you will need
1.
IMPORTANT!
The fixture controlled by the Z-Wave In-Wall Smart Switch must not
exceed 960W (incandescent); 1800W (15A) resistive or 1/2HP motor. The
switch is designed only for use with permanently installed fixtures.
Adding your device to a Z-Wave network
1. Follow the instructions for your Z-Wave certified
controller to add a device to the Z-Wave network.
2. Once the controller is ready to add your device, press and
release the top or bottom of the wireless smart switch (rocker).
Now you have complete control to turn your fixture
ON/OFF according to groups, scenes, schedules and
interactive automations programmed by your controller.
If your Z-Wave certified controller features remote access,
you can control your fixture from your mobile devices.
To remove and reset the device
1. Follow the instructions for your Z-Wave certified controller
to remove a device from the Z-Wave network.
2. Once the controller is ready to remove your device, press and
release the top or bottom of the wireless smart switch (rocker).
To return your switch to factory defaults
1. Quickly press ON (top) button three times then immediately
press the OFF (Bottom) button three times. The LED will
flash ON/OFF five times when completed successfully.
Note:
This should only be used if your network’s primary
controller is missing or otherwise inoperable.
4.
5.
To change color of the paddle
This step is optional. Before installation, you
may want to change the color of the paddle
to match your wallplate or decor.
1. Lift the air gap tab at the base of the paddle.
2. Push side tabs in on one side and then the other
to release paddle. Lift the cover up and off.
3. Simply put the new paddle onto the switch
by inserting the air gap and side tabs
and snapping securely into place.
Once this step has been completed, please return
to section 3.
1.
2.
This device supports Association Command Class (3 Groups)
• Association Group 1 supports Lifeline, Binary Switch Report
• Association Group 2 supports Basic Set and is controlled by pressing the ON or OFF button
with the local load
• Association Group 3 supports Basic Set and is controlled by double pressing the ON or OFF
button
• Each Association Group supports 5 total nodes
Z-WAVE INTEROPERABILITY
This product can be included and operated in
any Z-Wave network with other Z-Wave certified
devices from other manufacturers and/or other
applications. All non-battery operated nodes within
the network will act as repeaters regardless of
vendor to increase reliability of the network.
The GE-branded Add-on Switch is
required for multi-switch 3-way
or 4-way installations.
Connecting the traveler terminal of this
switch to a standard, non-GE-branded
switch will cause damage or result in
improper function. If this switch is a
part of a 3-way or 4-way multi-switch
installation, do not connect the traveler
wire or apply power until GE-branded
Add-on Switches are correctly installed.
For more information on 3-way or 4-way
installations, view the manual or quick-start
guide with the GE-branded Add-on Switch.
MANUAL • MANUEL • MANUAL
In-Wall
Smart Dimmers
Plug-in
Smart Dimmers
In-Wall
Add-on Switches
Purchase additional items at
EZzwave.com or visit your local retailer.
In-Wall Motion
Switch or Dimmer
Plug-in
Smart Switches
In-Wall
Smart Switches
Enbrighten
Smart LED Bulb
In-Wall
Smart Fan Control
Hinge Pin
Smart Door Sensor
Direct Wire,
40A Outdoor
Smart Switch
Portable
Smart Multi
Sensor
In-Wall
Tamper-Resistant
Smart Outlet
Plug-in
Outdoor Smart
Switch
46201
ZW4008
43072
ZW4008DV
In-Wall
Smart Switch
Montage mural
intelligent enfichable
Interruptor
de pared
inteligente
Convert any smart control* to a multi-location switch
*For a list of compatible devices, visit ezzwave.com
Smart Control Add-on Switches
To purchase an add-on switch or for more details,
visit ezaddonswitch.com.
Multiple Paddle
Colors Available
ezzwave.com/paddlecolors
READ IT OR WATCH IT
Read instructions or watch easy-to-follow
video. Scan QR code or visit goo.gl/5UAMUZ
E
C
B
A
D
WARRANTY
Jasco Products Company warrants this product to be free from manufacturing defects for two years from
the original date of consumer purchase. This warranty is limited to the repair or replacement of this product
only and does not extend to consequential or incidental damage to other products that may be used
with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states do not
allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or
consequential damage, so the above limitations may not apply to you. This warranty gives you specific rights,
and you may also have other rights which vary from state to state. Please contact our U.S.-based Consumer
Care at 1-800-654-8483 (option 1) between 7AM – 8PM CST or www.byjasco.com if the unit should prove
defective within the warranty period.
GARANTIE
Jasco Products Company garantit que ce produit est exempt de tout défaut de fabrication pour une période
de deux ans à compter de la date de l’achat original par l’acheteur. Cette garantie se limite exclusivement à la
réparation ou au remplacement de ce produit et n’est pas applicable aux dommages indirects ou accessoires
survenus sur d’autres produits utilisés avec ce produit. Cette garantie se substitue à toute autre garantie
expresse ou implicite. Certains États ne permettent pas de restrictions quant à la durée d’une garantie implicite
ou permettent l’exclusion ou la limitation des dommages indirects et accessoires; il se peut, par conséquent,
que cette garantie ne s’applique pas dans votre cas. Cette garantie vous confère des droits juridiques précis;
vous pouvez jouir d’autres droits qui peuvent varier d’un État à l’autre. Veuillez communiquer avec notre service
à la clientèle aux États-Unis au 1-800-654-8483 (option 1) entre 7 h et 20 h (heure normale du Centre) ou par
l’intermédiaire de notre site web www.byjasco.com si l’appareil s’avère défaillant au cours de la période de
garantie.
GARANTÍA
Jasco Products Company garantiza que este producto está libre de defectos de fabricación durante un
periodo de dos años a partir de la fecha original de compra por parte del consumidor. Esta garantía se limita
a la reparación o sustitución de este producto solamente y no se extiende a daños derivados o accidentales
causados a otros productos que se usen con esta unidad. Esa garantía remplaza a todas las demás garantías
expresas o implícitas. Algunos estados no autorizan limitaciones en cuanto a la duración de una garantía
implícita ni permiten la exclusión o limitación por daños accidentales o derivados; por lo tanto, puede que las
anteriores limitaciones no apliquen en su caso. Esta garantía le da a usted derechos específicos, y otros que
usted puede tener y que varían según el estado en el que usted reside. Si la unidad resultare defectuosa dentro
del periodo de garantía, Por favor, comuníquese con nuestro Centro de atención al cliente con sede en EE. UU.
al 1-800-654-8483 (opción 1) entre 7 y 20 h, Hora del Centro, o a través de nuestro sitio de internet
www.byjasco.com.
Jasco Products Company LLC, Building B
10 E. Memorial Rd. Oklahoma City, OK 73114.
SPECIFICATIONS
ZW4008
Power: 120VAC, 60Hz
Signal (Frequency): 908.4/916MHz
Maximum Loads: 960W, incandescent, 1/2HP motor or 1800W (15A) resistive
Range: Up to 150ft. line of sight between the wireless controller and the closest Z-Wave receiver module
Operating Temperature Range: 32-104° F (0-40° C)
Type 1 enclosure, independently mounted (vertical position only), operating control: type 1.c action, pollution degree (2),
impulse voltage (2500V), software class A
For indoor use only
Specifications subject to change without notice due to continuing product improvement
SPÉCIFICATIONS
ZW4008
Tension: 120VCA, 60Hz
Signal (fréquence): 908.4/916MHz
Charges maximales: 960W incandescent, moteur de 1/2HP ou résistance de 1800W (15A)
Portée : Distance à vue entre la télécommande et le module de réception Z-Wave le plus proche allant jusqu’à 150 pi (45.7m)
Plage de températures de fonctionnement: de 0 à 40° C (de 32 à 104° F)
Boîtier de type 1,monté indépendamment (position verticale seulement), intervention de type 1.c commande de
fonctionnement, degré de pollution (2), tension de choc de (2500 V), logiciel de classe A
Utilisation intérieure uniquement
En raison d’améliorations continues du produit, les spécifications peuvent faire l’objet de changements sans préavis
ESPECIFICACIONES:
ZW4008
Energía: 120VCA, 60Hz
Señal (Frecuencia): 908.4/916MHz
Cargas máximas: 960W, incandescente, 1/2HP motor o 1800W (15A) resistiva
Alcance: Hasta 150 pies (45.7m) en línea de visibilidad directa entre el control inalámbrico y el módulo receptor Z-Wave
más cercano
Rango de temperatura de funcionamiento: 0-40° C (32-104° F)
Recinto de tipo 1, independientemente montado (solo en posición vertical), control de operación: acción tipo 1.c , grado de
contaminación (2), voltaje de impulso (2500V), software de clase A
Para uso en espacios interiores solamente
Especificaciones sujetas a cambio sin aviso debido a continuas mejoras del producto
SPECIFICATIONS
ZW4008DV
Power: 120/277VAC, 60Hz
Signal (Frequency): 908.4/916MHz
Maximum Loads: 960W (120VAC)/1385W (277VAC) incandescent, 1/2HP (120/277VAC) motor or 1800W (15A)
(120/277VAC) resistive
Range: Up to 150ft. line of sight between the wireless controller and the closest Z-Wave receiver module
Operating Temperature Range: 32-104° F (0-40° C)
Type 1 enclosure, independently mounted (vertical position only), operating control: type 1.c action, pollution degree (2),
impulse voltage (4000V), software class A
For indoor use only
Specifications subject to change without notice due to continuing product improvement
SPÉCIFICATIONS
ZW4008DV
Tension: 120/277VCA, 60Hz
Signal (fréquence): 908.4/916MHz
Charges maximales: 960W (120VCA)/1385W (277VCA) incandescent, moteur de 1/2HP (120/277VCA) ou résistance de 1800W
(15A) (120/277VCA)
Portée : Distance à vue entre la télécommande et le module de réception Z-Wave le plus proche allant jusqu’à 150 pi (45.7m).
Plage de températures de fonctionnement : de 0 à 40° C (de 32 à 104° F)
Boîtier de type 1,monté indépendamment (position verticale seulement), intervention de type 1.c commande de
fonctionnement, degré de pollution (2), tension de choc de (4000V), logiciel de classe A
Utilisation intérieure uniquement
En raison d’améliorations continues du produit, les spécifications peuvent faire l’objet de changements sans préavis
ESPECIFICACIONES:
ZW4008DV
Energía: 120/277VCA, 60Hz
Señal (Frecuencia): 908.4/916MHz
Cargas máximas: 960W (120VCA)/1385W (277VCA) incandescente, 1/2HP (120/277VCA) motor o 1800W (15A)
(120/277VCA) resistiva
Alcance: Hasta 150 pies (45.7m) en línea de visibilidad directa entre el control inalámbrico y el módulo receptor Z-Wave
más cercano
Rango de temperatura de funcionamiento: 0-40° C (32-104° F)
Recinto de tipo 1, independientemente montado (solo en posición vertical), control de operación: acción tipo 1.c , grado de
contaminación (2), voltaje de impulso (4000V), software de clase A
Para uso en espacios interiores solamente
Especificaciones sujetas a cambio sin aviso debido a continuas mejoras del producto
Insert wires into holes, do not wrap wires
around screws.
Do not remove screws.
Loading ...