8
OPERATION
OTHER FUNCTIONS
Environmental protection function:
If no operation is detected within 60 seconds, all LED’s turn semi-bright.
When operation is detected, the LED’s enter full brightness immediately.
Water level protection function:
When the cooling function is rst turned on, the water pump works for 50
seconds. If the low water is detected, then the pump will stop working and
a buzzer alarms for 10 seconds.
Separation power off function:
When the water pump is removed from the tank, the unit will turn off
immediately.
Air dry function
If the honeycomb lter needs to be dried after using the cooler/humidier
function (e.g. before packing the unit away), press and hold the “fan speed”
button on the panel for 3 seconds to activate the air dry function.
When the air dry function is activated, the fan speed turns to high speed
automatically and runs for 20 minutes. During ‘Air dry’, other functions are
turned off and can’t be used. The high fan speed indicator will illuminate and
ash for the 20 minute duration.
If the “On/Off” button is pressed before the 20 minutes are complete, the
remaining ‘Air dry’ time won’t be saved, and you’ll need to start again.