28 29
Program option(Pr0)
Parameter options:(Pr7,Pr0)
Pr7: 7-day program function for the thermostat
Pr0: non-program function for the thermostat
Factory default: 7Pr
17.Filter replacement run time option( FIL)
Parameter options:(00-12)
This is a reminder to change or clean your air filter. This time can be set from 0 to
12 months in 1 month increments.
Factory default: 00
1.The thermostat will display the “ ” after a set time of operation.
2.Selection of 00 will cancel the function.
18.UV lamp replacement run time option(UUL)
Parameter options:(ON,OFF)
ON: It means starts to counting for 0 day to 400 day
OFF: It means cancel the function
Factory default:OFF
The thermostat will display the “ ” when UV time(400 days) has expired.
20.Remote sensor option(SEn)
Parameter options:(0,1,2)
0: No remote sensor
1: Outdoor control sensor (See Menu item 21 Heat pump temperature lockout)
2: Indoor sensor. if the thermostat is installed with an indoor remote sensor, display
will show the read temperature from the indoor sensor.
If the option is 1,2,please choose NTC-10 sensor.
Factory default:0