Complete Preparation
1. Determine and make all necessary cuts in the wall for the
vent system. Install the vent system before installing the
range hood. See the “Venting Requirements” section.
2. Determine the location where the power supply cable will be
run through the wall. Be sure that the location will be covered
by the chimney of the range hood.
3. Drill a 1
1
/
4
" (3.2 cm) hole at this location.
4. Pull enough power supply cable through the wall to allow for
easy connection to the terminal box.
5. Install the 10" (25.4 cm) square x 10" (25.4 cm) round
transition with damper to the top of range hood using the
three 4.2 x 8 mm screws.
NOTE: Your range hood requires you to purchase either
an internal type or an in-line (external type) blower motor
system.
For internal blower systems, there are blower motor
mounting parts in the blower motor installation packet that
must be added to the range hood prior to mounting the
range hood to the wall. See the “Install Range Hood Internal
Blower Motor” section and the instructions supplied with the
blower motor.
Install Range Hood
1. Remove the grease lter. See the “Range Hood Care”
section.
2. Using two or more people, hang range hood on two
mounting screws through the mounting slots on back of
range hood.Level the range hood and tighten upper
mounting screws.
3. Install two 5 x 45 mm lower-mounting screws and tighten.
Install Range Hood Internal Blower Motor
NOTE: Your range hood requires you to purchase either an
internal type or an in-line (external type) blower motor system.
See “Blower Motor System” in the “Accessories” section.
Prepare the Internal Blower System
IMPORTANT: Perform steps 1-4 before mounting the range
hood.
1. Remove grease lters from range hood. See the “Range
Hood Care” section.
2. Install the 6 mm nuts to the outside top of the range hood at
the proper location for the selected motor system.
Two 6 mm nuts are required for the single motor system.
Clip the nuts into the small square notches located at the
left and right sides (centered) of the square to round vent
transition.
Five 6 mm nuts are required for the dual motor system.
Clip the nuts into the small square notches, one located
in the front of the square to round vent transition and the
other four located at the left and right ends of the square
to round vent transition.
3. Disconnect the electrical connector to the heat lamp.
A
B
A. Mounting screws
B. Mounting slots
A
A. Lower-mounting screws
A
A
A
B
A. Clip nut (6 mm) locations for dual motor assembly (quantity five)
B. Clip nut (6 mm) locations for single motor assembly (quantity two)
Loading ...
Loading ...
Loading ...