Jenn-Air KXW9748YSS

User Manual - Page 13

For KXW9748YSS.

PDF File Manual, 56 pages, Download pdf file

Loading ...
Loading ...
Loading ...
13
2. Connect the wires from the wiring conduit to the wires from
the motor electrical plug cable inside the in-line blower
housing terminal box.
3. Use UL Listed wire connectors and connect the black wires
(C) together.
4. Use UL Listed wire connectors and connect the white wires
(D) together.
5. Use UL Listed wire connectors and connect the red wires (E)
together.
6. Use UL Listed wire connectors and connect the blue wires
(F) together.
7. Use UL Listed wire connectors and connect the gray wires
(G) together.
8. Connect the green (or yellow/green) ground wire to the
green/yellow ground wire (H) in the terminal box using UL
Listed wire connectors.
9. Reinstall the in-line blower terminal box cover and screw.
10. Reinstall the front cover of the in-line blower housing and
secure it with 10 mounting screws.
Electrical Connection Inside Range Hood Between In-
line Blower System and Range Hood
1. With the range hood mounted (see the “Install Range Hood”
section), locate the wiring cable connector inside the range
hood.
2. Connect the six-wire connector assembly supplied with the
in-line blower motor system to the mating cable connector
from the range hood.
3. Locate the terminal box inside the range hood and install a
1/2" (1.3 cm) UL Listed or CSA approved strain relief (see
“Complete Preparation” in the “Prepare Location” section).
4. Run the wire ends from the 6-wire connector assembly
through the 1/2" (1.3 cm) strain relief, leaving enough wire
length to make the wiring connections. Tighten the strain
relief screws.
5. Connect the wires from the six-wire connector assembly
to the wires from the wiring conduit inside the range hood
terminal box.
6. Connect the same color wires to each other (black to black,
white to white, etc.) using UL Listed wire connectors.
NOTE: Connect the green (or green/yellow) ground wire from
the wiring conduit to the green (or bare) ground wire from the
home power supply using UL listed wire connectors (see the
“Make Electrical Power Supply Connection to Range Hood”
section).
7. Go to “Make Electrical Power Supply Connection to Range
Hood” section.
A
B
C
D
E
F
G
H
I
A. UL Listed or CSA approved
1/2" (1.3 cm) wiring conduit
B. UL Listed wire connectors
C. Black wires
D. White wires
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or yellow/green)
and green/yellow wires
I. Motor electrical plug cable
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
A
B
C
D
E
F
G
H
I
A. UL Listed or CSA approved
1/2" (1.3 cm) wiring conduit
B. UL Listed wire connectors
C. Black wires
D. White wires
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or yellow/green)
and green/yellow wires
I. Motor electrical plug cable
Loading ...
Loading ...
Loading ...