INSTALLATION INSTRUCTIONS
Installation
WARNING!
This product is heavy and requires two persons for installation.
WARNING!
Failure to install the screws or fixing device in accordance with these instructions
mayresult in electrical hazards.
The manufacturer is not liable for any damage caused by not following these instructions.
1
Prepare for installation.
Before installing your cooker hood:
Please read the instructions carefully.
Unpack the cooker hood and check that all functions are working.
Ensure that the voltage (V) and the frequency (Hz) indicated on the serial plate
match the voltage and frequency at the installation site.
The stainless steel and glass surfaces of the cooker hood are very easilydamaged
during installation if grazed or knocked by tools. Take care to protect the surfaces
during installation.
Protect the hob surface below with cardboard, or the like, toprevent damage
occurring whilst the cooker hood isbeinginstalled above.
2
Fit the 150mm ducting adapter with non return flap tothecooker hood using the
screwssupplied.
3
Provide an opening on the underside of the cupboard (seeproduct and cabinetry
cutout dimensions).
4
Remove the filters and face plate of the cooker hood.
IMPORTANT!
Venting directly into the cabinet with no ducting and louvered vent is not permitted.
To recirculate your perimeter insert range hood:
1
Determine the desired location of the 150mm louvered vent on your cabinetry.
Thelouvered vent can be placed on the side or front of your cabinet provided there
issufficient clearance from the surrounding cabinetry to enable ventilated air to
recirculate back into your kitchen.
Note: Placement of the louvered vent on the top of your cabinetry is not recommended.
This should only be done if objects can be prevented from falling through the louvers
into the blower.
2
Create a cutout in your cabinet to fit the 150mm louvered vent. Place the louvered vent
on the hole created and secure (A).
3
Connect the blower outlet to the louvered vent with a length of 150mm rigid ducting,
and secure the joints with aluminum tape. Ensure there is no slack in the ducting.
Recirculation
venting options
A
Side To p
Front