SLEEP/ECO MODE
The selected temperature will increase by 1°C over
30 minutes. The temperature will then increase by
another 1°C after an additional 30 minutes. This new
temperature will be maintained for 7 hours before
it returns to the originally selected temperature.
Sleep/Eco mode will end and the unit will continue to
operate as originally programmed.
Note: This feature is unavailable under FAN or DRY mode.
WATER DRAINAGE
Remove the upper drain plug from the back of the
unit and attach 3/4ÿhose (not included).
NOTE: Make sure the hose is secure so there are no
leaks.
Direct the hose toward the drain, making sure that
there are no kinks. Place the end of the hose into the
drain and make sure the end of the hose is down to
let the water flow smooth.
When the water level of the bottom tray is full,
the unit will beep 8 times and display “PI”. The
air conditioning/dehumidification process will
immediately stop, while the fan motor continues to
operate. Carefully move the unit to a drain location,
remove the bottom drain plug and allow the water
to drain. Reinstall bottom drain plug and restart the
machine until the “PI” symbol disappears.
NOTE: Always install drain plugs and hose firmly to
prevent leaking.