14 Part Number 000015236 Rev 00 11/17
Installation Instructions Section 2
Refrigeration System Installation
Remote Condensing Unit Only
QuietQube®
Ice Machine
Remote Condensing
Unit
Line Set*
RNF1100C
RFF1300C
RFF2200C
RCUF1000
RCUF1200
RCUF2200
RC-21
RC-31
RC-51
*Line Set Suction Line Liquid Line
RC 21/31/51
5/8 inch
(15.9 mm)
3/8 inch
(9.5 mm)
Important
Manitowoc remote systems are only approved and
warranted as a complete new package. Warranty on the
refrigeration system will be void if a new ice machine
head section is connected to pre-existing (used) tubing or
condensing units or vice versa.
USAGE WITH NON-MANITOWOC CONDENSING UNITS
Manitowoc Remote Condensing Units are specifically
designed for usage with a QuietQube® Ice Machine Head
Section. Standard condensing units and Non-Manitowoc
condensing units are not approved for use with a
QuietQube® Ice Machine Head Section.
,
Caution
The 60-month compressor warranty (including the
36-month labor replacement warranty) will not
apply if the Manitowoc Ice Machine and Manitowoc
Remote Condensing Unit are not installed according
to specifications. This warranty also will not apply if
the refrigeration system is modified with a condenser,
heat reclaim device, or other parts or assemblies not
manufactured by Manitowoc Ice.
Factory Equipment Refrigeration Amounts
ICE MACHINE HEAD SECTION
Each ice machine condensing unit ships from the factory
with a R-404A refrigerant charge appropriate for the entire
system operation. The serial tag on the ice machine indicates
the refrigerant charge. The refrigerant charge is sufficient to
operate the ice machine in ambient temperatures between
-20°F (-28.9°C) and 120°F (48.9°C). With line set lengths of up
to 100 feet (30.5 m).
n
Warning
Potential Personal Injury Situation
The QuietQube Condensing Unit contains the refrigerant
charge. Installation and brazing of the line sets must
be performed by a properly trained and EPA-certified
refrigeration technician aware of the dangers of dealing
with refrigerant-charged equipment.
REFRIGERATION LINE SETS/TRAP KIT
Refrigeration Rated Tubing and Trap Kits are shipped capped
with atmospheric pressure.
n
Warning
Installation of a QuietQube® Condensing Unit may require
the use of special equipment for placement. Trained and
qualified personnel are required for proper rigging and
lifting.