User Manual Black+Decker BPP10WTB 14,000 BTU Portable Air Conditioner with Remote Control

Black+Decker BPP10WTB 14,000 BTU Portable Air Conditioner with Remote Control - Use Manual - Use Guide PDF.
Documents: Go to download!
  • User Manual - (English)

file thumbnail

User Manual

SET UP & USE

PARTS & FEATURES

SPECIFICATIONS

BPP05WTB

Unit dimensions (W x D x H): 17.32” x 14.05” x 27.16” Unit Weight approx. 51.1 lbs.

BPP06WTB

Unit dimensions (W x D x H): 17.32” x 14.05” x 27.16” Unit Weight approx. 54.8 lbs.

BPP08WTB

Unit dimensions (W x D x H): 17.32” x 14.05” x 27.16” Unit Weight approx. 63.1 lbs.

BPP08HWTB

Unit dimensions (W x D x H): 17.32” x 14.05” x 27.16” Unit Weight approx. 64.5 lbs.

BPP10WTB

Unit dimensions (W x D x H): 17.32” x 14.05” x 27.16” Unit Weight approx. 65.1 lbs.

BPP10HWTB

Unit dimensions (W x D x H): 17.32” x 14.05” x 27.16” Unit Weight approx. 66.6 lbs.

Electric Requirements: 115V ~ 60Hz

INSTALLATION GUIDE

LOCATION

  • The air conditioner should be placed on a firm floor to minimize noise and vibration. For safe and secure positioning, place the unit on a smooth, level floor strong enough to support the unit.
  • The unit has casters to aid placement, but it should be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects.
  • The unit must be placed within reach of a properly rated grounded socket.
  • Never place any obstacles around the air inlet or outlet of the unit.
  • Allow 12 inches to 36 inches of space from the wall with window for efficient air-conditioning.

SUGGESTED TOOLS FOR WINDOW KIT INSTALLATION

  • Screwdrivers (medium size Phillips)
  • Tape measure or ruler
  • Knife or scissors
  • Saw (In the event that the window kit needs to be cutdown in size because the window is too narrow for direct installation)

WINDOW SLIDER KIT INSTALLATION

Your window slider kit has been designed to fit most standard “Vertical” and

Horizontal” window applications; however, it may be necessary for you to improvise/modify some aspect of the installation procedures for certain types of window. Minimum and maximum window openings:

MAXIMUM : 47.2” (120 cm) MINIMUM : 27.5” (70 cm)

DOUBLE-HUNG SASH/SLIDING CASEMENT WINDOW INSTALLATION

  1. Cut the foam seal (adhesive type) to the proper length and attach it to the window sash.
  2. Attach the window slider kit to the window sash. Adjust the length of the window slider kit according to the width of window. Shorten the adjustable window kit if the width of window is less than 27.5”.
  3. Cut the foam seal (adhesive type) to the proper length and attach it on the top of the window.
  4. Close the window securely against the window slider kit.
  5. Secure the window slider kit to the window sash.
  6. Cut the foam seal to an appropriate length and seal the open gap between the top window frame and outer window frame.

EXHAUST HOSE INSTALLATION

The air exhaust hose and hose inlet must be installed or removed from the portable air conditioner in accordance with the way it is being used:

COOL, DEHUMIDIFY, HEAT (Heat models BPP08HWTB and BPP10HWTB only:

FAN: Air exhaust hose and hose inlet should be connected to the portable air conditioner

1. Connect hose inlet to one end of air exhaust hose. Push hose inlet over the end of the hose, push in slightly and then start threading it on in a clockwise direction. (see Fig. 1)

2.Connect hose outlet to other end of air exhaust hose. Push hose outlet over the end of the hose, push in slightly and then start threading it on in a clockwise direction. (see Fig. 2)

3.Align the tabs on the hose inlet into the slots over the air outlet, insert and push down. (see Fig. 3)

4. Insert the hose outlet into the window panel.

5. Affix the hose outlet into the window slider kit and seal. (Fig. 4 & 5)

CONTROL PANEL

OPERATING FROM THE CONTROL PANEL

The Control Panel enables you to manage all the main functions of the appliance, but to fully exploit its potential, you must use the remote control.

TURNING THE APPLIANCE ON

  • Plug into the dedicated electrical outlet.
  • Press the button until the appliance comes on. The last function active when it was turned off will appear.
  • Never turn the air conditioner off by unplugging from the outlet. Always press the button , then wait for a few minutes before unplugging. This allows the appliance to perform a cycle of checks to verify operation.
  • Press the MODE button until the light corresponding to the required Mode lights up.

COOL MODE

Ideal for hot weather when you need to cool the room.

To set operation of the appliance correctly, press the + or – buttons until the desired temperature is displayed. (See Fig. 7)

Then select the fan speed by pressing the Fan Speed Button until the light corresponding to the required fan speed lights up:

HIGH: The Fan operates at maximum to reach the required temperature as rapidly as possible.

MED: Reduces Fan noise level but still maintains cooling.

LOW: For quiet operation.

DEHUMIDIFY

Press the “MODE” button until the "DEHUMIDIFY” indicator light comes on.

  • Under this mode, you cannot select a fan speed or adjust the temperature. The fan motor operates at LOW speed.
  • Keep window and door closed for the best dehumidifying effect.
  • Exhaust hose attachment is not required to reduce humidity, however it is recommended in very humid rooms so the warm air can be exhausted outside.

DEHUMIDIFICATION MODE

  • It is recommended that the dehumidification drain and drain hose can be used for continuous drainage.
  • FULL TANK - When the water level reaches a predetermined level, the full tank” indicator light goes on. The unit will have to be drained.

FAN MODE

  • Press the “MODE” button until the "FAN” indicator light comes on.
  • Press the speed button to select HIGH, MEDIUM or LOW fan speed. The temperature cannot be adjusted.
  • Exhaust hose attachment is not required in this mode.

HEAT MODE (Heat models BPP08HWTB and BPP10HWTB only)

  • Press the “MODE” button until the "HEAT” indicator light comes on.
  • Press the + or – buttons to select your desired room temperature. The temperature can be set within a range of 61°F-88°F.
  • Press the speed button to select HIGH, MEDIUM or LOW fan speed.

DRAINING IN

TIMER

  • To set the AUTO STOP timer. When the unit is ON, press the TIMER button.
  • Press the + or – button to select the AUTO TIME by 1 hour increments, up to 24 hours. The LED Display will indicate the remaining time. Press the TIMER button again. The TIMER indicator light illuminates to show that the AUTO STOP program is initiated.
  • To set the AUTO START timer. When the unit is OFF, press the TIMER button.
  • Press the + or – button to select the AUTO TIME by 1 hour increments, up to 24 hours. The LED Display will indicate the remaining time. Press the TIMER button again. The TIMER indicator light illuminates to show that the AUTO START program is initiated.
  • Pressing the POWER button or the TIMER button will cancel the AUTO START/STOP timed program and the timer indicator light will not be illuminated

SWING INDICATOR LIGHT

When this light is illuminated, it indicates that the air swing is activated from the remote and the louvers will move up and down.

SLEEP INDICATOR LIGHT

When this light is illuminated, it indicates that SLEEP has been activated from the remote control and that the temperature will gradually adjust.

OPERATING FROM THE REMOTE CONTROL

BATTERY INSTALLATION (BATTERIES NOT INCLUDED)

(1) Slide open the battery compartment cover.

(2) Insert 2 × “AAA”batteries as shown.

(3) Slide back the battery cover.

Point the remote control at the receiver on the appliance. The remote control must be no more than 7 meters away from the appliance (without obstacle between the remote control and the receiver).

The remote control must be handled with extreme care. Do not drop it or expose it to direct sun light or sources of heat.

REMOTE CONTROL

POWER BUTTON: Press to Turn ON or OFF

TIMER BUTTON: Used to set a delay start or shut down time.

MODE BUTTON: Each time you press the button COOL, DEHUMIDIFY, FAN, HEAT models BPP08HWTB and BPP10HWTB is selected)

°C / ˚F SELECTOR BUTTON: Select Fahrenheit or Celsius.

INCREASE: Increase the temperature setting.

DECREASE: Decrease the temperature setting.

LED BUTTON: Illuminates the LED screen on the unit.

SWING BUTTON: Activates the air swing of the louvers.

FAN SPEED BUTTON: Used to select the HIGH, MED or LOW Fan speed.

SLEEP BUTTON: Gradually adjusts the temperature.

POWER BUTTON

  • Press to Turn Air Conditioner ON or OFF. Press LED button to illuminate the LED screen on the unit.
  • Will show on the remote LED screen when buttons are pressed to show that the remote control is sending a signal to the air conditioner.

MODE BUTTON

  • Press the mode button to scroll through COOL , DEHUMIDIFY , FAN , HEAT (Heat models BPP08HWTB and BPP10HWTB only)
  • The corresponding symbol will illuminate on the LED display to indicate which mode is selected.

COOL

  • Select the target temperature 61˚F – 88˚F (16˚C – 31˚C) by pressing the or – buttons until the desired temperature is displayed on the LED screen.
  • Press the Fan Speed Button to select Low, Medium, or High Speed.

DEHUMIDIFY

Ideal for reducing humidity.

  • Keep window and door closed for the best dehumidifying effect.
  • Exhaust hose attachment is not required to reduce humidity, however it is recommended in very humid rooms so the warm air can be exhausted outside.

Draining in Dehumidify mode

  • It is recommended that the dehumidification drain and drain hose be used for continuous drainage.
  • FULL TANK - When the water level reaches a predetermined level, the “full tank” indicator light goes on. The unit will have to be drained.
  • In this mode, fan speed is selected automatically by the appliance and can not be set manually.

FAN

Press the Fan Speed Button to select Low, Medium or High Speed.

HEAT

  • Select the target temperature 61˚F – 88˚F (16˚C – 31˚C) by pressing the + or – buttons until the desired temperature is displayed on the LED screen.
  • Press the speed button to select HIGH, MEDIUM or LOW fan speed.

SWING

  • Press this button to activate the air swing of the louvers. Press it again to deactivate.

TIMER

  • To set the AUTO STOP timer. When the unit is ON, press the TIMER button. The TIME ON/OFF symbol on the remote LCD display will blink.
  • Press the + or – button to select the AUTO TIME by 1 hour increments, up to hours. The Remote LCD Display will indicate the selected time. Press the TIMER button again to set the selected time. There will be a steady TIME ON/ OFF symbol on the remote LCD display and the TIMER indicator light will be illuminated on the control panel of the unit to show that the AUTO STOP program is initiated.
  • To set the AUTO START timer. When the unit is OFF, press the TIMER button. The TIME ON/OFF symbol on the remote LCD display will blink.
  • Press the + or – button to select the AUTO TIME by 1 hour increments, up to hours. The Remote LCD Display will indicate the selected time. Press the TIMER button again to set the selected time. There will be a steady TIME ON/ OFF symbol on the remote LCD display and the TIMER indicator light will be illuminated on the control panel of the unit to show that the AUTO START program is initiated.
  • Pressing the POWER button or the TIMER button will cancel the AUTO START/ STOP timed program and the timer indicator light will not be illuminated

SLEEP

  • The SLEEP function gradually adjusts the temperature of the rooms to provide a comfortable environment. Press the SLEEP button to activate.
  • In COOL mode, the temperature will increase 1°F after an hour and 2°F after 2 hours.
  • In HEAT mode, the temperature will decrease 1°F after an hour and 2°F after 2 hours.
  • To cancel this setting press the SLEEP button again.

°C / °F SELECTOR BUTTON

  • When the appliance is powered on, press the °C / °F button, then you can select the unit of temperature from Fahrenheit or Celsius.

WATER DRAINAGE FOR COOLING AND HEAT MODES

This air conditioner is equipped with auto water evaporation so the water compartment would not typically fill in cooling or heating mode unless there is high humidity. Water drainage will generally only be required at the end of the season for these modes. (see START-END OF SEASON OPERATIONS).

Intermittent Draining

  • Unplug the unit from the power source. Carefully move the unit to a drain area over your basement floor or drip pan (not included). Remove the bottom drain cap.
  • Let the water drain away and replace the drain cap. Restart the machine until the error codes E2 or E4 disappears. If the error repeats, call for service.

Continuous Draining

  • Unplug the unit from the power source. Remove the bottom drain cap. While doing this operation some residual water may spill so have a drip pan (not supplied) to collect the water.
  • Connect the drain hose (supplied) as shown in the diagram. The water can be continuously drained through the hose into a floor drain or drip tray.
  • Turn on the unit.

WAIT 3 MINUTES BEFORE RESUMING OPERATION

  • After the unit has stopped, it cannot be restarted for 3 minutes. Operation will automatically restart after 3 minutes.

Continuous Draining for Dehumidification Mode

Unplug the unit from the power source.

Remove the drain cap located in the back center of the unit. While doing this operation some residual water may spill so have a drip pan (not supplied) to collect the water.

Connect the drain hose (supplied) as shown in the diagram. The water can be continuously drained through the hose into a floor drain or bucket.

Turn on the unit.

WAIT 3 MINUTES BEFORE RESUMING OPERATION

  • After the unit has stopped, it cannot be restarted for 3 minutes. Operation will automatically restart after 3 minutes.

CLEANING & CARE

CLEANING

CLEANING THE CABINET

You should clean the appliance with a slightly damp cloth then dry with a dry cloth.

  • Never saturate the air conditioner with water.
  • Never use petrol, alcohol or solvents to clean the appliance.
  • Never spray insecticide liquids or similar near the air conditioner.

CLEANING THE FILTER

To keep your air conditioner working efficiently, you should clean the evaporator filter every week of operation.

The filter is housed in the intake grill.

Use a vacuum cleaner to remove dust accumulations from the filter.

If it is very dirty, immerse in warm water and rinse a number of times.

The water should be luke warm.

After washing, leave the filter to dry then re-insert the filter.

START - END OF SEASON OPERATIONS

START OF SEASON CHECKS

Make sure the power cable and plug are undamaged.

Follow the installation instructions precisely.

END OF SEASON OPERATIONS

See Water Drainage section to make sure the air conditioner is completely drained of water.

Clean the filter and dry thoroughly before reinstalling.

TROUBLESHOOTING

BEFORE YOU CALL FOR SERVICE

IF THE AIR CONDITIONER FAILS TO OPERATE:

A) Check to make sure that the air conditioner is plugged in securely. If it is not, remove the plug from the outlet, wait 10 seconds and plug it in again securely.

B) Check for a blown circuit fuse or a tripped main circuit breaker. If these seem to be operating properly, test the outlet with another appliance.

Troubleshoot your problem by using the chart below. If the air conditioner still does not work properly, contact BLACK+DECKER customer service center or the nearest authorized service center. Customers must never troubleshoot internal components.

Unit does not start when pressing ON/OFF button

  • Water full indicator light is on. LED display indicates "E2” in COOL mode or “E4” in HEAT mode.
    • Drain the water
  • Room temperature is lower than set temperature cooling mode)
    • Reset the temperature

Not cool enough

  • The windows or doors in the room are not closed
    • Make sure all the windows and doors are closed
  • There are heat sources inside the room
    • Remove the heat sources if possible
  • Exhaust air duct is not connected or blocked
    • Connect the duct and make sure it can function properly
  • Temperature setting is too high
    • Decrease the set temperature
  • Air filter is blocked by dust
    • Clean the air filter
  • The unit will take approx 3 minutes of operation before cooling occurs
    • A mircoprocessor control delays the compressor from operating until 3 mins have passed.

Noisy or vibration

  • The surface is not level or not flat enough
    • Place the unit on a flat, level surface if possible

Unit does not run and water full indicator light is on. LED display indicates “E2” in COOL mode or “E4” in HEAT mode.

  • The unit needs to be drained.
    • Refer to water drainage section.

LED display “E0” , “E1”, E3”

  • EO - Room temperature sensor issue
  • E1- Condenser temperature sensor
  • E3- Evaporator temperature sensor
    • Contact the Customer Satisfaction Center for assistance with error code.

Remote is not working

  • Nothing Appears on the LED screen.
    • Press the LED button on the remote. If it does not illuminate, change batteries.
  • The temperature and symbols appear on the LED screen but the selection cannot be changed.
    • Make sure the remote is being pointed at the remote control receiver on the unit within 23 feet away and that there are no obstructions.


See other models: BPP08WTB BPT06WTB BPP06WTB BPT05WTB BAB-2438

Black+Decker BPP10WTB | Pages: 27 | Created on: 2021-02-23 | File type: PDF | Filename: 1748535_bpp10wtb.pdf | Size: 2.08 MB | Language: English

Download User Manual

Product Infomation and Reviews - BPP10WTB photo

BPP10WTB Photo

T: @manualsFile

https://manualsFile.com