Loading ...
Loading ...
Loading ...
INSTALLATION INSTRUCTIONS
PREPARING THE ENCLOSURE
Gloves and safety goggles should be worn during
installation.
It is not recommended to install the appliance into a
corner or directly beside a wall. The door will need
to be opened more than 90° to allow full extension
of the shelves. If it is necessary to place the unit next
to a wall or in a corner, leave at least 2-4 inches (5-
10 cm) of space between the wall and the appliance
to allow for the door opening.
The cabinet opening must be at least 24 inches (61
cm) wide by 25 inches (63.5 cm) deep.
If the appliance will be built in with the leveling foot,
the height of the opening must be at least 35 inches
(88.9 cm).
If the appliance will be built in with the casters
installed, the height of the opening must be at least
37 inches (94 cm).
Note: The listed depth requirement is assuming
that the electrical outlet is located in the adjacent
cabinetry or fl ush mounted in the rear wall, not
surface mounted inside the enclosure.
If the electrical outlet is located inside adjacent
cabinetry, cut a 1.5 inch (3.8 cm) diameter hole to
admit the power cord. If the cabinet wall is metal,
the hole edge must be covered with a bushing or
grommet.
REQUIRED TOOLS
• Safety goggles
• Gloves
• Tape measure
• Carpenter square
• Level
• Flashlight
Electric drill with hole bit
COMPRESSOR HOUSING COVER REMOVAL
If the appliance will be built into an enclosure, the
compressor housing cover must fi rst be removed.
This is to allow air fl ow around the compressor
so that it does not over heat. Keep the cover and
screws in a safe place so that they can be used
again in future if necessary.
Electrical Access
El
ectric
al
Acces
s
*If electrical outlet in
adjacent cabinetry
35 - 37 in
(88.9 -
94 cm)
2 in (5 cm)
6 in
(15.2 cm)
1.5 in (3.8 cm) diameter
24 in (61 cm)
90°
25 in
(63.5 cm)
5
Loading ...
Loading ...
Loading ...