Loading ...
Loading ...
Loading ...
INSTALLATION INSTRUCTIONS
DISCONNECTING THE LIQUID PROPANE CYLINDER
Turn the grill burner valves “OFF” and make sure the grill is cool.
Turn the Liquid Propane cylinder valve “OFF” by turning clockwise until it stops.
Detach the regulator assembly from the cylinder valve by turning the quick coupling nut counterclockwise.
Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap
on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may result
in leakage of propane.
LEAK TESTING – GENERAL
Although gas connections on the grill are leak tested prior to shipment, a complete leak test must be per-
formed at the installation site. Before each use, check all gas connections for leaks using the procedures
listed below.
If the smell of gas is detected at any time, you should immediately check the entire system for leaks.
BEFORE TESTING
Make sure all packing materials have been removed from the grill, including the burner tie-down straps.
Make a solution of one part liquid detergent and one part water. You will need a spray bottle, brush, or rag to
apply the solution to the ttings. For the initial leak test, make sure the Liquid Propane cylinder is full.
TO TEST
1. Turn the burner valves off.
2. Turn the Liquid Propane cylinder valve counterclockwise to open the valve.
3. Apply the soap solution to all gas ttings. Soap bubbles will appear where a leak is present.
4. If a leak is present, immediately turn the gas supply “OFF” and tighten leaky ttings.
5. Turn the gas back “ON” and recheck.
6. Should the gas continue to leak from any of the ttings, turn the gas supply “OFF” and contact customer
service at 866-994-6390 or email [email protected]
7. If there is evidence of excessive abrasion or wear, or the hose is cut, it must be replaced prior to the outdoor
cooking gas appliance being put into operation.
Only those parts recommended by the manufacturer should be used on the grill. Substitutions will void the
warranty.
INSTALLER FINAL CHECK
Maintain specied clearance of 36 inches from combustible materials and construction.
All internal packaging has been removed.
The hose and regulator are properly connected to the Liquid Propane cylinder.
The unit has been tested and is free of leaks.
The gas supply shutoff valve has been located.
All burners are installed.
• Keep the instruction manual for future reference.
m WARNING
Check all gas supply ttings for leaks before each use. Do not use the grill until all connections have been
checked and do not leak. Do not smoke while leak testing. Never leak test with an open ame.
m WARNING
Do not store grill indoors unless the cylinder is disconnected. Do not store cylinder in a building, garage, or
any other enclosed area, and keep out of reach of children at all times.
8
Loading ...
Loading ...
Loading ...