Sub-Zero UC15I SubZero 15 Inch BuiltIn Indoor Panel Ready Ice Machine

User Manual - Page 5

For UC15I.

PDF File Manual, 32 pages, Read Online | Download pdf file

UC15I photo
Loading ...
Loading ...
Loading ...
subzero.com
|
5
SITE PREPARATION
Electrical
Installation must comply with all applicable electrical codes.
Although it can be located anywhere on the back wall, it
is recommended that the electrical supply be placed in an
adjacent cabinet or in the lower right of the opening. Refer
to the illustration below. A separate circuit servicing only this
appliance is required.
Model UC-15I(P)O is designed and safe for use in outdoor
applications. When installed outdoors, a ground fault circuit
interrupter (GFCI) is required to reduce the risk of electrical
shock. A GFCI is not recommended for use with the indoor
model and may cause interruption of operation.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
E
E
E
Electrical supply location.
CAUTION
The outlet must be checked by a qualied electrician to
be sure that it is wired with the correct polarity. Verify
that the outlet is properly grounded.
WARNING
Do not use an extension cord, two-prong adapter or
remove the power cord ground prong.