User Manual - Page 31

For DVE45T6200W.

Loading ...
Loading ...
Loading ...
English 31
Installation
Running the vent blockage test
1. Make sure the drum is empty, and then close the door. (If there are any clothes or
other items in the drum, the test will not give accurate results.)
2. Press the Power button to turn the dryer on, then simultaneously press and hold the
Adjust Time and Dryness buttons for 3 seconds. “InS” appears in the dryer’s display.
(If you have started other procedures before the Vent Blockage Test, the dryer will not
enter the Vent Blockage Test mode.)
3. Press the Start/Pause (Hold to Start) button. The Vent Blockage Test starts immediately.
During the test, the number indicator makes a circle in 6 clockwise steps. The test takes
about 2 minutes. Do not open the door during the test.
4. After 2 minutes, when the test is complete, the results are displayed and the dryer
sounds a tone. If status of the duct system is normal, “0” appears and the dryer
sounds a completion tone. If the duct system cannot exhaust properly, the check code
appears, and the dryer sounds an alarm tone. For description about the code, see the
Installation check codes” section on page 32.
If there are any other problems, an information code appears in the display. For
description about the code, see the “Information codes” section on page 55.
- To stop or cancel the Vent Blockage Test, press the Power button to turn off your
dryer.
- The results remain on the display for about 5 minutes and then automatically turn
off. You can turn the results off immediately by pressing the Power button.
NOTE
During or after the test, the internal drum is hot. Use caution to prevent burns. The
Vent Blockage Test is used to check for problems in the current duct system when the
dryer is installed for the rst time.
If the test result displays check code (the duct system is blocked ), refer to the “Ducting
requirements” section on page 15 and the “Exhaust ducting guide” section below, and
then take proper measures to correct any problems. If the test is suspended, it could
result in incorrect results. Follow the proper procedures when testing the dryer.
Even if the test result is normal (“0”), the duct system could be blocked slightly.
Properly install all duct work according to the installation instructions in this manual.
Untitled-13 31 2020-07-14  3:30:07
Loading ...
Loading ...
Loading ...