Operating The Product
Top Light
The unit is supplied with a top light to illuminate the fuel bed. This feature can be switched
between on or o depending on your preference. Simply sliding the cover back and forth allows
you to control this light.
LED indicators - see Fig. 3
Three LED’s as shown in Fig. 3 indicate the setting for a couple of seconds every time you
change the setting.
One LED means ON (ame eect only, no heat), two LED’s means 1kW heat and all three LED’s
are on to indicate full 2kW heat setting.
Remote control - see Fig. 4
The maximum range of use is ~ 5metres.
The buttons on the remote control have the same function as the swiches on the heater.
For details on the function please refer to the ‘Controls’ section above.
Warning: It takes time for the receiver to respond to the transmitter.
Do not press the buttons more than once within two seconds for correct operation.
Battery information - see Fig. 4
1. To activate the remote control remove the battery isolation strip, which is used to ensure your
remote control reaches you fully charged.
2. Remove the screw, follow the instruction on the back of the remote to release the battery
housing. Slide the battery cover open. Install Lithium battery in the battery holder. The positive
(+) side of the battery faces up. Close the battery cover and replace the screw
3. Only use CR2025 or CR2032 size of batteries.
Discard leaking batteries
Dispose of batteries in the proper manner according to provincial and local regulations.
Any battery may leak electrolyte if mixed with a dierent battery type, if inserted incorrectly, if all
the batteries are not replaced at the same time, if disposed of in a re, or if an attempt is made
to charge a battery not intended to be recharged.
Thermostat (T) - see Fig. 2
In order to maintain a certain room temperature, set the controller to ‘max.’. Operate the
appliance at full power until the required room temperature is reached. Set back the thermostatic
controller until the appliance switches o with an audible “click”. This temperature will be kept
almost constant by the thermostatic control switching on and o automatically. Please note
that the appliance can only be switched on when the thermostat setting is higher then the room
temperature.
Instructions for tting Coal Option - see Fig. 5
Introduction
Your re is provided with a coal eect option. Simply follow the instructions given below.
Removal of Log Eect
Remove the screws securing the log eect assembly and slide out (see Fig. 5).
Fitting Coal Eect
Fit the coal eect in position and secure with the screws (see Fig. 5).
Place the coal lumps on the fuel bed. A plastic glove is provided for handling the coal.
Note: The log eect should be stored away for possible future use.