REPLACEMENT PART LIST
No. Description BH0420002
(2000W)
BH0420003
(3000W)
BH0420004
(4000W)
BH0420005
(6000W)
1 Tube Element BH8180001 BH8180002 BH8180001 BH8180002
2 Front Cover BH8180003 BH8180004 BH8180003 BH8180004
3 Element End Cover Set BH8180005 BH8180006 BH8180005 BH8180006
4 Junction Box Cover & Seal Set BH8180007 BH8180007 BH8180007 BH8180007
5 Mounting Bracket Set (Short) BH8180008 BH8180008 BH8180008 BH8180008
6 Mounting Bracket Set (Long) BH8180009 BH8180009 BH8180009 BH8180009
7 Ceiling Recess Kit BH8180010 BH8180011 BH8180010 BH8180011
8 Tube Suspension Kit BH8180012 BH8180012 BH8180012 BH8180012
9 Chain Suspension Kit BH8180013 BH8180013 BH8180013 BH8180013
SYMPTOM POSSIBLE CAUSE (S) CORRECTIVE ACTION
Element does not energize 1. Defective element
2. Improper connection
1. Replace element
2. Check connection to power
outlet
Not enough heat 1. Heater too small for application
2. Heater mounted too high or too
far
1. Add additional heater(s)
2. Decrease mounting height or
distance
Too much heat 1. Heater too large for application
2. Heater mount too low or too close
1. Replace with smaller heater
2. Increase mounting height or
distance
Hot spot in Tube 1. Heater is not level
2. Grease or moisture on tube
1. Adjust to level mount
2. Clear tube-replace if problem
persists