19510300500_AUS English, All Logos to be Ariston {PDF Created 18/01/13 22:28:00}
3
Important Information TD4200HC Issue 1
Step 1
Open the Condenser Cover
- hold the handle and pull towards you
Step 2
Remove the condenser by rotating
the 3 clips then pulling the
condenser towards you. (There may
be some water in the tubes this is
normal
)
TD4199HC_1 TD4200HC_2
Step 3
Flush the condenser, from the rear
with water, to remove any fluff
deposits.
Step 4
Refit the condenser unit - ensure that the
unit is pushed in fully, all 3 clips are re-
secured and the positioning arrows on the
front of the condenser are pointing
upwards.
TD4108HC_3.JPG TD4200HC_3
TD4200HC_4
GB
Condenser Unit
You must clean the fluff from the condenser ever
y
month
Rotate 3 Clips Check That:
- The positioning arrows are
pointing upwards.
- The 3 clips re secured back
in their ‘lock’ position..
Failure to clean the condenser could cause premature failure of your dryer