Clearance Dimensions 24’’/30’’/36’’/48’’
• This range may be installed directly adjacent to existing 36”
(91.4 cm) high base cabinets.
IMPORTANT: The side trim MUST be 3/8” (0.95 cm)
above the adjacent base cabinet countertop. This can be
accomplished by raising the unit adjusting the legs.
The range CANNOT be installed directly adjacent to
sidewalls, tall cabinets, tall appliances, or other side
vertical surfaces above 36”(91.4 cm) high. There must be a
minimum of 6” (15.2 cm) side clearance from the range to
such combustible surfaces above the 36” (91.4 cm) counter
height.
• Within the 6” (15.2 cm) side clearance to combustible
vertical surfaces above 36” (91.4 cm), the maximum wall
cabinet depth must be 13” (33.0 cm) and wall cabinets
within this 6” (15.2 cm) side clearance must be 18” (45.7
cm) above the 36” (91.4 cm) high countertop.
• Wall cabinets above the range must be a minimum of 42”
(106.7 cm) above the range cooking surface for the full
width of the range. This minimum height requirement does
not apply if a range hood is installed over the cooking
surface.
CAUTION
Burn hazard
To avoid risk of personal injury; the use of cabinets for storage above the appliance may resultin a potential burn hazard.
Combustible items may ignite, metallic items may become hot and cause burns. If a cabinet storage is to be provided the risk
can be reduced by installing a range hood that projects horizontally a minimum 5” (12.7 cm) beyond the bottom of cabinets.
Note: If a range hood is installed, wall cabinets above the
range have a different minimum clearance height.
36’’ 30’’ 24’’
min 6"
min 6"
36"
13"
min 18"