Problem Recommended Steps
Control panel
6. Buttons on the control
panel are not illuminated.
- Re-start the wine dispenser by pressing the main power
switch at the back of the machine.
- Ensure that the main power button is on and there is
power to the machine.
Preservation and
Dispensing
7. Wine does not pour when
the dispensing button is
pressed.
- Ensure that the wine bottle is installed correctly onto the
locking piston assembly (6-7).
- Ensure that the Locking piston assembly (with wine
bottle) is securely engaged into the chilling chamber (8-
9).
- Ensure that the check valve is installed onto the cartridge
head properly and is securely tightened.
- Wine will not dispense if the chamber or another
chamber is actively in the preservation mode:
i. Wait for the preservation cycle to be completed
within the chamber in which that function is in-
process, or
ii. Cancel the preservation process by pressing the
“Preserve” button on the control panel.
8. A wine bottle is securely
installed but preservation
mode is not working.
- If a wine bottle is installed securely, the light should be
blue. If no light is illuminated, neither the preservation
mode nor dispensing mode is active.
- Open the glass door and ensure the bottle is installed
correctly onto the locking piston assembly and that the
locking piston assembly is engaged into the chilling
chamber. Close the door and the machine should reset.
- Ensure the check valve is tightened onto the cartridge
head. If you have reinstalled the check valve, reset the
preservation mode by opening and closing the door after
you have reinstalled the check valve. Preservation should
begin and the blue light should illuminate.
9. Wine is dispensing slowly. - Ensure that the wine bottle is installed correctly onto the
locking piston assembly Ensure it is securely engaged
into the chilling chamber.
- Ensure that the check valve is installed onto the cartridge
head properly and is securely tightened.
- Clean the bottle tube and the check valve by running
clean water through the system or following the cleaning
instructions. Dry all parts and reinstall.
- Replace the check valve and reset the chilling chamber
function by opening and closing the door.
10. The check valve drips. - Ensure that the check valve is installed onto the cartridge
head properly and is securely tightened.
- Clean the check valve (14-15).
- Replace the check valve and reset the chilling chamber
function by opening and closing the door.
18
KR_WINE_DISPENSER_NAFTA_NC00119132_NC00119132 18/07/13 08:37 Page18