PAGE 8 INSTALLATION REQUIREMENTS
ELECTRICAL REQUIREMENTS cont.
POWER SUPPLY CORD (See Fig.2)
Wiring Requirements
For model HWE15XCR, HWR15XCR
115-volt (103.5 minimum to 126.5 maximum)
15-amp time-delay grounded fuse or circuit breaker
Use on single outlet circuit only.
For model HWE18VCR, HWR18VCR
230/208 volt (187 min. to 253 max.)
15-amp time-delay fuse or circuit breaker
Use on single outlet circuit only.
For model HWE24VCR, HWR24VCR
230/208 volt (187 minimum to 253 maximum)
20-amp time-delay grounded fuse or circuit breaker
Use on single outlet circuit only.
REQUIRED GROUNDING METHOD (See Fig.2)
This air conditioner must be grounded. This air conditioner is equipped with a power
supply cord that has a 3 prong grounding plug. The power supply cord must be plugged
into a mating, grounded 3 prong outlet, and grounded in accordance with all local codes and
ordinances. If a mating outlet is not available, it is the customer’s responsibility to contact a
qualified electrician and ensure that a properly grounded 3 prong
outlet is installed.
POWER SUPPLY CORD (See Fig.3)
NOTE: Your air conditioner's plug may differ slightly in appearance
from the one shown.
A. Reset button
B. Test button
This room air conditioner is equipped with an
a leakage current detection interrupter (LCDI)
power supply cord required by UL. This power supply cord contains a current detection device.
If the power supply cord is crushed, this device will detect current leakage and power will be
disconnected from the air conditioner. If this power supply cord
is damaged, it cannot be
repaired and must be replaced with a cord from the product manufacturer. If the power supply
cord is damaged call Haier Customer Service: 1-877-337-3639.
RESET
TEST
A
B
Fig. 3
Fig. 2
HWE15XCR
HWR15XCR
HWE18VCR
HWR18VCR
HWE24VCR
HWR24VCR
115V
15 Amp
230V
15 Amp
115V
15 Amp
230V
15 Amp
230V
20 Amp
115V
15 Amp
230V
15 Amp
230V
20 Amp