Gaggenau AI400720 48 Inch Island Chimney Range Hood with 630

User Manual - Page 9

For AI400720.

PDF File Manual, 56 pages, Read Online | Download pdf file

AI400720 photo
Loading ...
Loading ...
Loading ...
9
The extractor hood can be used in exhaust air
and circulating air mode. The standard setting
is exhaust air mode.
Exhaust-air mode
Installation accessories for exhaust air mode
Stainless steel-design ventilation duct:
AD 010-016 for ceiling heights of 87
13
/
16
”-94
7
/
8
AD 010-026 for ceiling heights of 94
7
/
8
”-107
1
/
2
AD 010-036 for ceiling heights of 107
1
/
2
”-117
11
/
16
”.
The air which is drawn in is cleaned by the grease
filters and conveyed to the exterior by a pipe
system.
Appliance dimensions Exhaust air
Circulating-air mode
Installation accessories for circulating air mode
Stainless steel-design ventilation duct:
AD 010-126 for ceiling heights of 94
7
/
8
”-107
1
/
2
AD 010-136 for ceiling heights of 107
1
/
2
”-117
11
/
16
”.
The air which is drawn in is cleaned by the grease
filters and an activated carbon filter and conveyed
back into the kitchen.
An activated carbon filter must be installed to bind
odours in circulating-air mode (see ”Removing and
installing the grease filters”).
The complete installation set as well as the
replacement filters are available from specialist
outlets, customer service or the Online Shop. The
accessory number can be found at the end of the
operating instructions.
The socket must be attached at least 6
11
/
16
” below
the ceiling.
Appliance dimensions Circulating air
Operating modes
min. 22
13
/
16
’’
max. 55
11
/
16
’’
min.
6
1
/
8
’’
min. 22
13
/
16
’’
max. 59
13
/
16
’’
min.
1
3
/
8
’’
Loading ...
Loading ...
Loading ...