50
en Technical specications
Problem Cause Solution
Very frequent display that
descaling is necessary.
Water is too hard. Insert a water filter and activate
(see chapter “Menu – Water
filter).
Beverage dispenser
blocked.
Clean the beverage dispenser
and milk system intake.
Display shows
Please clean brewing unit,
then replace
Brewing unit is soiled. Clean the brewing unit.
Too much pre-ground
coffee in the brewing unit.
Clean the brewing unit. Place no
more than two level measuring
spoons of ground coffee in the
drawer.
The mechanism of the
brewing unit is stiff.
Clean the brewing unit (see the
section “Daily maintenance and
cleaning”).
Display shows
Please restart appliance
Appliance is too warm. Leave the appliance to cool
down.
Brewing unit is soiled. Clean the brewing unit.
Display shows
Descaling insufficient.
Repeat process
Incorrect or insufficient
descaler or excessive scale
existing on appliance.
Perform descaling programme
again.
Display shows
Please let appliance
cool down
Appliance is too hot. Switch off appliance for 30
minutes.
Display shows
Error
Please contact hotline
The appliance has a fault. Please contact the hotline.
If you are unable to solve the problem, always call the hotline!
You will find the telephone numbers at the back of these instructions�
Technical specifications
Power connection (voltage – frequency) 220-240 V – 50/60 Hz
Power rating 1500 W
Maximum static pump pressure 15 bar (TE651.., TE653.., TE654..)
19 bar (TE655.., TE657..)
Maximum water tank capacity (without filter) 1.7 l
Maximum capacity of the coffee bean container ~300 g
Length of power cable 100 cm
Dimensions (H x B x D) 385 x 301 x 458 mm
Weight, empty 10-12 kg
Type of grinding unit Ceramic