Other Components continued:
Atthispointyoucanaccess
theprimaryaircontrol
damperassembly,
thermostaticactuator
assemblyandthedamper
releaselever. Althoughthese
shouldn’tneedtobereplaced,
theycanbeeasily. The
primary aircontrol damper
assemblycanbereplacedby
removingthesmallspring
handlefromthefrontofthe
unit,thenslidingtheassemblyout. Replacebyslidingthenewassemblythroughthesamehole
andtherod
throughthe
frontofthestove. Replacethespringhandle. Thethermostatic
actuator assemblycanbereplacedbyusinga5/16”sockettoremovethetwoscrewsthathold
theassembly.Installthenewassemblyusingthe
sametwo
screws. Thedamper release lever
canbereplacedbyremovingthe½”bolt. Whenreinstallingthedamperbesureitisinstalled
thesameaswhenremoved.
OPTIONALACCESSORIES
Blower:Thewoodstovewasalsodesignedforusewithaconvectionblowerforadditionalheat
circulation. Thestoveisconstructedwithsideconvectionchannelswhichallowtheroomair
blowertopickupheatfromthehottestregionsofthestoveandtransferitintothehome. The
mountingscrewsfortheblowerareinstalledintotherearconvectionchannelatthefactory;
mountingthebloweronlyrequiresa5/16”openendorsocketwrenchtoremovethese screws
andinstalltheblower.
Whenroutingthepowercord,takecaretokeepawayfromhotareasoftheunitandremember
thatthisblowerisforuseonlywiththestove. Pleaseseethediagrambelowforclarificationon
theroomairblowerinstallation.
ThisunitcanusetheAC‐16(whichcomesstandardwiththeunit)ortheAC‐30upgradeblower.
Bothareinstalledusingthefourfactoryinstalled5/16”screws.
Theoptionalheatcirculationbloweronthisstoverequiresperiodiclubrication;thislubricationshouldbeperformed
nolessthaneverythreemonthsofnormaloperation. Toproperlylubricatetheblower,useaneyedropperor
similardispensingdevicetodrip5‐7dropletsofSAE20oilinto
theoil
portonthesideoftheblowermotor
Warning:Disconnectpower
fromfanbeforeinstallation.
(4)5/16”head,self‐tapping