SPECIFICATIONS
Heating Specifications
•
MaximumBurnTime**
.................................................................................
6‐8hours
•
ApproximateSquareFootageHeated***
....................................................
2000sq.ft.
•
Firebox
Capacity............ ................................................................................35
pounds
•
FlueCollar
..................................................................................................
6.0in.round
Dimensions(Inches)
EPAandSafetyComplianceSpecifications
EPAComplianceStatus……....... Certifiedtocomplywith2020particulateemission
standardsusingcribwoodfuel.
U.S.TestStandard:USEPA40CFRPart60,Subpart60.536
ParticulateEmissions ……………………………1.956grams/hr
COEmissions……………………………………….1.659grams/min
HeatOutputRange……………………………..11,129–24,369Btu/hr
Efficiency……………………………………………73.77%(HHV)
TestedToEPATestMethod28A,ASTME2780,ASTME2515,ULC/ORD‐C1482&ULCS627‐
00
Notesforthisunit:Productmayvaryslightlyfromdiagram.Clearancesaretheminimumfor
thisunitandmayneedtobeincreasedinthereartohaveproperventclearances.Followall
ventingmanufacturerclearancesandlocalcodes.
***‐Themaximumheatingcapacityofthisunitcanvarygreatlybasedonclimate,constructionstyle,insulationandamyriadofotherfactors.
UsethisinformationinconjunctionwithaBTUlosscalculationforyourhometodetermineifthisunitwillbesufficientforyourneeds.