Sub-Zero Customer Care 800.222.7820
Maintenance
WATER FILTER REPLACEMENT
The water lter should be replaced every six months, after
a prolonged shutdown or after 8000 ice making cycles.
‘REPLACE FILTER’ will illuminate on the control panel
indicating the water lter needs to be replaced. The ice
machine bypasses the lter when it is removed, so the water
supply does not need to be turned off.
Replacement Sub-Zero water lters can be ordered online
at subzerowolfstore.com. For questions, contact Sub-Zero
customer care at 800-222-7820.
IMPORTANT NOTE: Poor water quality may require more
frequent water lter replacement.
To replace water lter:
1 To remove the water lter, rotate one-quarter turn
counterclockwise and the lter will pop out. Refer to the
illustration below.
2 Reverse the process to install the new lter.
3 Touch and hold ‘CLEAN’ for 6 seconds to reset the
indicator.
Water lter location.
WATER
FILTER
Cleaning
CONDENSER CLEANING
CAUTION
Before cleaning the condenser, turn power off at the
control panel. Wear gloves to avoid injury from sharp
condenser ns.
The condenser is located behind the kickplate. To access,
remove the kickplate. Use a soft bristle brush and vacuum
to remove dust and lint from the condenser. Clean the con-
denser every six months. Refer to the illustration below.
IMPORTANT NOTE: To avoid damaging condenser ns,
vacuum in the direction of the ns.
CAUTION
Failure to clean the condenser could result in tempera-
ture loss, mechanical failure or damage.
Condenser location.
CONDENSER
CARE RECOMMENDATIONS