8
Conversion to another type of gas
This gas stovetop corresponds to the categories
specified on the rating plate. By changing nozzles, it
is possible to convert the appliance to any of the
gases listed on the plate. The conversion kit can be
obtained from our customer service. With some
models, the conversion kit is included in the scope of
delivery.
Only a licensed specialist is authorized to switch the
appliance to another gas type.
Before carrying out the conversion, turn off the
electricity and gas supply.
Changing the low burn nozzle
1 Remove pan supports and all burner parts.
2 Remove control knobs. Unscrew fastening screws
(three 7 mm nuts on each burner and two Torx
T20 on the wok burner) and and carefully detach
stovetop.
3 The low burn nozzles are located in the gas valve
and are screwed in from above. Turn the black
plastic part so that the recess is above the nozzle.
Screw out nozzle and take nozzle out with small
pliers.
4 Insert the new nozzles as specified in the nozzle
table. The nozzles must be screwed in fully.
Changing the full burn nozzle: normal and large
burner
1 Remove securing clips on the burner pipes.
Remove burner pipes. Leave the electrode
connected. Unscrew burners (Torx T20) and and
pull off the burner from the burner pipes.
2 Remove nozzles and O-ring by hand.
3 Check that O-ring is correctly positioned in new
full-burn nozzles. Push nozzles onto burner pipes.
Do not bend burner pipes!
4 Push the burners onto the supply lines. Put on
securing clips. Screw the burners back on.
5 Set air-regulating tube to correct dimension after
loosening the screw (see nozzle table). Tighten
screw again.
/