R290 has a low GWP (Global Warming Potential) of 3.
The air conditioner contains about 235 g of R290 refrigerant gas.
Do not use or store in an unventilated space with an area smaller than 11.3m
2
per unit.
The room must be such as to prevent stagnation of possible leaks of refrigerant gas as
there could be a danger of fire or explosion hazard should the refrigerant come into
contact with electric heaters, stoves or other sources of ignition.
If the appliance is installed, used or stored in an unventilated room, the room must be
such as to prevent stagnation of possible leaks of refrigerant gas as there could be a
danger of fire or explosion should the refrigerant come into contact with electric heaters,
stoves or other sources of ignition.
Do not use the product and contact the retailer for advice, if damage has occurred to
the unit which may have compromised the refrigerant system.
Any repairs or maintenance must only be carried out on the unit by a suitably qualified
engineer. Before opening and servicing the unit the authorized engineer must be in
possession of a copy of the manufacturer’s service manual and must follow the safety
information contained within it to ensure all hazards are minimized.
The refrigerant system should not be perforated or punctured.
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition
sources (For example: open flames, an operating gas appliance or an operating
electric heater)
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Energy Saving and Unit Safety Protection Tips
Do not cover or restrict the airflow from the outlet or inlet grills.
For maximum performance the minimum distance from a wall or objects should be
50cm. The unit is fitted with a thermal cut off sensor that will prevent overheating.
Keep the filters clean. Under normal conditions, filters should only need cleaning once
every three weeks (approximately). Since the filters remove airborne particles, more
frequent cleaning maybe necessary, depending on the air quality.
For the initial startup set the fan speed to maximum and the thermostat to 4-5 degrees
lower than the current temperature. After, set the fan switch to low and set the
thermostat to your desired setting.
To protect the unit we recommend not using the cooling function when the ambient
temperature is higher than 35°C.
To protect the unit we recommend not using the heating function when the ambient
temperature is lower than 7°C. Use alternative heating to raise the room temperature
to 10°C than start the air conditioner in heat mode and set it to the desired temperature.
Heating by heat pump will take longer but is much more efficient than any other form of
heating and ideal for maintaining a constant room temperature.