BEFORE
USE
HOW TO DISMANTLE
AND REASSEMBLE
THE METAL PLATE
1
4 5
2
3
HOW TO REMOVE THE METAL
PLATE:
Grip the metal plate holding it by the seal, and
unscrew the central nut in an anti-clockwise
direction. Remove the nut and keep it in a safe
place. Press the spring loaded screw spindle to
release the metal plate. Remove the metal plate.
HOW TO TAKE THE VALVE COVER OFF:
Hold the valve cover by its middle part (as shown); Then turn it slightly to unclip
it. Clean the valve cover, paying special attention to the inside (check that there
is no left over food).
PUTTING THE METAL PLATE BACK
IN PLACE:
Grip the metal plate by the seal as shown in
the picture. Line up the metal plate with the
central screw spindle and press it flat against
the underside of the lid. Put the nut back on with
the flat side facing the metal plate and turn it
clockwise, tightening it as far as it will go.
PUTTING THE VALVE COVER
BACK:
Take the valve cover as shown in the picture
(gripping the middle). Line up the interior
circular shape with the three hooks and then
push so that the valve cover clips on (you should
hear a “click” sound). The valve cover must be
close up against the inside of the lid.
ACCESSING THE DECOMPRESSION BALL:
When the lid is completely cool, turn the ball cover, anti-clockwise, so
as to bring the
marker into position . Lift off the cover. Remove
the ball, and gently clean it, along with its cover, with water and some
washing-up liquid. Dry the ball using a soft cloth, then put it back in
position. Put the ball cover back in place, and the marker
in position
. Lock it by turning the ball cover so that the marker is opposite the
pictogram “closed” .
Note: The metal decompression ball may still be hot
even when the lid has cooled.
The notches on the rotating inner part of the lid must be correctly aligned with
the notches on the rim of the bowl otherwise the lid will not lock when closed.