CIRCUIT REQUIRED
208V, 60Hz 240V,60Hz
12 AMP 15 AMP
This oven is dual rated, designed to be connected to either 208/240V AC,
60Hz, 3-wire, two-phase power supply
The electrical supply should be 3-wire two-phase AC� Install a suitable conduit
box (not furnished)� An appropriately-sized, U-listed conduit connector must
be used to correctly attach the conduit to the junction box�
3-WIRE BRANCH CIRCUIT
Where local codes allow the connection of green
ground wire from the oven to the branch circuit white
neutral wire:
• If local codes permit, connect the green ground
wire from the oven and the white neutral wire
from the oven to the branch circuit neutral wire
(gray or white colored wire)�
• Connect the red and black wires from the oven
to the corresponding wires in the junction box�
• Refer to Figure 5�
ELECTRICAL REQUIREMENTS
WARNING: Electrical Shock Hazard
• DO NOT use an extension cord�
• Failure to follow these instructions can result in death, fire, or electrical shock�
• Any additions, changes or conversions required in order for this appliance to satisfactorily meet the
application needs must be made by a qualified service personnel in accordance with the manufacturer’s
instructions and all codes and requirements of the authority having jurisdiction� Failure to follow the
instructions could result in serious injury or property damage� The qualified service personnel performing
this work assumes responsibility for the conversion�
• This appliance needs to be installed directly to the main (without a plug)� To do so, follow instructions in
the “Three-Wire Connection” section on page 12� If you wish to install this appliance directly to the main
(without a plug), it must be installed by a qualified service personnel�
• DO NOT operate this appliance using a 2-prong adapter or an extension cord� If a 2-prong wall receptacle
is the only available outlet, it is the personal responsibility of the consumer to have it replaced with a
properly grounded 3-prong or 4-prong wall receptacle installed by a qualified service personnel� Severe
shock or damage to the range may occur if the range is not installed by a qualified service personnel�
• This appliance features a pilotless electric ignition for energy savings and reliability� It operates on a
208-240V/50-60Hz 12-15 Amp power supply
• A separate circuit, protected by a 15 amp time delay fuse or circuit breaker, is required�
• For personal safety, the appliance must be properly grounded�
ELECTRICAL INSTALLATION
WARNING: It is the responsibility and obligation of the consumer to contact a qualified service personnel to
ensure the electrical installation is adequate and conformance with all local codes and ordinances�
IMPORTANT: The power supply to the appliance must be cut off before any adjustments or maintenance work
is done on it� Air duct is supposed to use in ventilation�
Figure 5
Black Wires
Red Wires
Green Wire
Neutral Wire
White Wire
Cable from Oven
Cable from Power Supply
UL Listed Conduit
Connector