Loading ...
Loading ...
Loading ...
49-80549-4
13
1
INSTALL FRAMING FOR HOOD
SUPPORT
IMPORTANT³Framing must be capable of
supporting 100 lbs.
If
drywall is present, mark the screw hole locations for
the top mounting brackets. Remove the template.
&XWDZD\HQRXJKGU\ZDOOWRH[SRVHYHUWLFDOVWXGV
at the bracket location indicated on the template.
,QVWDOODKRUL]RQWDOVXSSRUWDWOHDVWµ[µEHWZHHQ
two wall studs at the mounting screw location. The
horizontal support must be flush with the room
side of the studs. Use cleats behind both sides of
the support to secure to wall studs.
NOTE: 2 horizontal supports will be needed if there is
a stud located between the horizontal screw locations
(see figure).
IMPORTANT: Reinstall drywall for an even mounting
surface.
Centerline of
installation
space
View from rear
cleats
µ[µPLQ
mounting
support
DUCTWORK, WIRING LOCATIONS
'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
Locate the template packed with the literature.
–Measure from the floor to the top of the cooking
surface. Add hood installation height determined on
pages 8 and 13. Mark that location.
Use a level to draw a straight pencil line on the wall.
–Tape the template in position along the penciled line.
CHECK TO BE SURE THE TEMPLATE IS LEVEL.
Ceiling ducting:
,IGXFWZRUNZLOOYHQWVWUDLJKWXSWRWKHFHLOLQJ
Use a level to draw a line straight up, from the
centerline on the template to the ceiling.
Measure 5” from the back wall to the centerline of
DQµKROHRQWKHFHLOLQJ
NOTE: If drywall is not present, add drywall thickness
to the 5” dimension.
Wall Ducting:
,IGXFWZRUNZLOOYHQWWRWKHUHDU
Use a level to draw a line straight up from the
centerline on the template.
0HDVXUHDWOHDVWµDERYHWKHSHQFLOOLQHWKDW
indicates the bottom installation height, to the
FHQWHUOLQHRIDQµGLDGXFWKROH+ROHPD\EH
elongated for duct elbow.)
HOUSE WIRING LOCATION:
7KHMXQFWLRQER[LVORFDWHGRQWKHWRSOHIWVLGHRIWKH
hood.
Wiring should enter the back wall at least 18” above
the bottom of the hood and within 5” of the left side
of the centerline.
µPLQRSHQLQJIRUGXFWZRUN
REAR WALL
MOUNTING TEMPLATE
Vertical Centerline
ALIGN BOTTOM EDGE
WITH PENCIL LINE
INDICATING BOTTOM
OF THE HOOD
11-7/16"
Installation Height
Horizontal Line
C
L
DRILL 2 (TWO) 3/16" PILOT HOLES THROUGH STUDS OR REAR WALL SUPPORT
10-1/8"
12-08 JR
2"
DRILL 2 (TWO) 3/16" PILOT HOLES THROUGH STUDS OR REAR WALL SUPPORT
12-1/2"
WALL VENT IS 27-3/4" MIN.
ABOVE THE INSTALLATION
HEIGHT
31-14772 Printed in Mexico
Ceiling
House Wiring
Location
C
L
5”
18”
Min.
Wall vent
µ
min. above
installation
height
5” c enterline
to wall
,167$//$7,21³9(17('727+(2876,'(
Installation Instructions
Loading ...
Loading ...
Loading ...