20 49-60767-1
Performance Data Sheet - Model: GE Appliances RPWFE
Use Replacement Cartridge RPWFE.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF
International against NSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below.
The following pharmaceutical reduction claims have not been certified by NSF International.
Claims tested and verified by independent laboratory:
Substance
Reduction Average Influent
NSF specified
Challenge
Concentration
Avg %
Reduction
Average Product
Water
Concentration
Max Permissible
Product Water
Concentration
NSF
Test Report
Atenolol 1088 ng/L N/A 99.5% 5.0 ng/L N/A J-00103221
Fluoxetine 845 ng/l N/A 99.4% 5.0 ng/L N/A J-00103221
Ibuprofen 898 ng/L N/A 98.8% 9.9 ng/L N/A J-00103726
Progesterone 945 ng/L N/A 99.4% 5.5 ng/L N/A J-00103727
Trimethoprim 403 ng/L N/A 99.5% 2.0 ng/L N/A J-00103221
It is essential that the manufacturers recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as
advertised. See Installation Manual for Warranty information.
Application Guidelines/Water Supply Parameters
Service Flow 0.5 gpm (1.89 lpm)
Water Supply Potable Water
Water Pressure 25-120 psi (172-827 kPa)
Water Temperature 33°F-100°F (0.6°C-38°C)
Note: While the testing was performed under standard laboratory
conditions, actual performance may vary. Contaminant reduction
testing is conducted every five years by certifying agency to
maintain certification.
Replacement Cartridge: RPWFE. For estimated costs of
replacement elements please call 1.877.959.8688 or visit our
website at www.geapplianceparts.com.
WARNING
To reduce the risk associated with ingestion of contaminants:
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before and
after the system. Systems certified for cyst reduction may be
used on disinfected water that may contain filterable cysts.
NOTICE
To reduce the risk of water leakage or flooding, and to
ensure optimal filter performance:
Read and follow use instructions before installation and use of
this system.
Installation and use MUST comply with all state and local
plumbing codes.
Do not install if water pressure exceeds 120 psi (827 kPa). If
your water pressure exceeds 80 psi, you must install a pressure-
limiting valve. Contact a plumbing professional if you are
uncertain how to check your water pressure.
Do not install where water hammer conditions may occur. If
water hammer conditions exist you must install a water hammer
arrester. Contact a plumbing professional if you are uncertain
how to check for this condition.
Do not install on hot water supply lines. The maximum operating
water temperature of this filter system is 100º F (38º C).
Protect filter from freezing. Drain filter when temperatures drop
below 33ºF (0.6ºC).
Change the disposable filter cartridge every six months or sooner
if you observe a noticeable reduction in water flow rate.
Failure to replace the disposable filter cartridge at recommended
intervals may lead to reduced filter performance and cracks inthe
filter housing, causing water leakage or flooding.
Product certified by NSF International, which requires resting
of Product every 5 years for material safety, structural integrity,
performance claims.
Capacity 170 Gallons (643.5 Liters). Contaminant Reduction Determined by NSF testing.
Substance Tested
for Reduction
Average
Influent
NSF specified
Challenge
Concentration
Avg %
Reduction
Average
Product Water
Concentration
Max Permissible
Product Water
Concentration
NSF Reduction
Requirements
NSF
Test Report
Chlorine Taste and Odor 2.0 mg/L 2.0 mg/L ± 10% 97.4% 0.05 mg/L N/A  J-00102044
Nominal Particulate Class
,WRP 7,633,333 pts/mL At least 10,000 particles/mL 99.0% 71,850 pts/mL N/A  J-00106249
Asbestos 109 MF/L
10
7
to 10
8
fibers/L; fibers
JUHDWHUWKDQPLQOHQJWK 99.99% 0)/ N/A  J-00102069
Atrazine 0.009 mg/L 0.009 mg/L ± 10% 94.4% 0.0005 mg/L 0.003 mg/L N/A J-00102058
Benzene 0.016 mg/L 0.015 mg/L ± 10%± 96.4% 0.0001 mg/L 0.005 mg/L N/A J-00102065
Carbofuran 0.08 mg/L 0.08 mg/L ± 10% 98.8% 0.001 mg/L 0.04 mg/L N/A J-00102059
Cyst* 104,750 cysts/L Minimum 50,000 cysts/L 99.99% 3 cyst//L N/A  J-00102057
Lead @ pH 6.5 0.140 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00102052
Lead @ pH 8.5 0.158 mg/L 0.15 mg/L ± 10% 98.3% 0.002 mg/L 0.010 mg/L N/A J-00102053
Mercury @ pH 6.5 0.006 mg/L 0.006 mg/L ± 10% 91% 0.0004 mg/L 0.002 mg/L N/A J-00102054
Mercury @ pH 8.5 0.006 mg/L 0.006 mg/L ± 10% 88.3% 0.0003 mg/L 0.002 mg/L N/A J-00104087
Lindane 0.002 mg/L 0.002 mg/L ± 10% 99% 0.00002 mg/L 0.0002 mg/L N/A J-00102063
P-Dichlorobenzene 0.222 mg/L 0.225 mg/L ± 10% 99.8% 0.0005 mg/L 0.075 mg/L N/A J-00102067
Toxaphene 0.015 mg/L 0.015 mg/L ± 10% 93.5% 0.001 mg/L 0.003 mg/L N/A J-00102061
2, 4-D Reduction 0.218 mg/L 0.210 mg/L ± 10% 99.9% 0.0001 mg/L 0.07 mg/L N/A J-00102064
VOC 0.278 mg/L 0.300 mg/L ± 10% 97.7% 0.0015 mg/L N/A  J-00102070
*Based on the use of Cryptosporidium parvum oocysts.
REPLACEMENT
ELEMENT
Tested and certified by NSF International against
NSF/ANSI Standard 42 and Standard 53 in model
GE Appliances RPWFE for the reduction of the
claims specified on the performance data sheet.