DRYER VENTING REQUIREMENTS
1. Connect gas supply to dryer. Use a pipe thread compound
approvedforthetypeofgassupplied.Ifexiblemetaltubing
is used, be certain there are no kinks.
If necessary for service, depending on model:
Open the toe panel by removing the 2
1
4
"hex-headscrewsfrom
the bottom of the panel. Then lift up on the panel while pulling
the bottom of the panel away from the dryer.
OR
Open the toe panel. Use a putty knife to press on the toe panel
lock located at the center top of the toe panel. Pull downward
on the toe panel to open. Toe panel is hinged at the bottom.
Make Gas Connection
GAS SUPPLY CONNECTION
The outside end of main vent should have a sweep elbow
directed downward.
If main vent travels vertically through the roof, rather than
through wall, install a 180° sweep elbow on end of vent at least
2 ft. (610 mm) above surface of roof.
Theopeninginwallorroofshallhaveadiameter1/2"(13mm)
largerthanventdiameter.Ventshouldbecenteredinopening.
Do not install screening over end of vent for best performance.
12" min.
(305 mm)*
A main vent can be used for venting a group of dryers.
Themainventshouldbesizedtoremove5663l/min.(200CFM)
of air per dryer. Large-capacity lint screens of proper design
may be used in main vent if checked and cleaned frequently.
The room where the dryers are located should have make-up
air (air supply) equal to or greater than CFM of all the dryers
in the room.
Back-draft dampers are available from your distributor and
should be installed in the vent of each dryer to keep exhausted
air from returning into dryers and to keep exhaust in balance
within main vent. Unobstructed return air openings are required.
Although usually each single-load dryer should have an
unobstructed outdoor air opening of 24 in.
2
(154cm
2
) (based
on 1 in.
2
[6.5cm
2
]per1,000BTU[252kcal]),commonmake-up
air openings are also acceptable. Set up common openings so
the make-up air is distributed equally to all of the dryers. Keep
in mind that the coverage area must be increased by 33% to
account for the use of registers or louvers over the openings.
Also, make-up air openings should not be installed near the
location where exhaust vents exit the building.
Each vent should enter the main vent at an angle pointing in the
directionoftheairow.Ventsenteringfromtheoppositeside
should be staggered to reduce the exhausted air from interfering
with the other vents.
The maximum angle of each vent entering the main vent should
be no more than 30.°
Keepairopeningsfreeofdrycleaninguidfumes.Fumescreate
acids which, when drawn through the dryer heating units, can
damage dryers and items being dried.
A clean-out cover should be located on the main vent for
periodic cleaning of the vent system.
NOTE: For more dryer venting information, please refer to
Whirlpool document W10100920.
If an Exhaust Hood Cannot be Used Multiple Dryer Venting
24" min.
(610 mm)
* Minimum clearance above any
accumulation of snow, ice, or
debris such as leaves
30˚ max.
Air ow
Air Flow
2.Opentheshut-ovalveinthegassupplylineandmakesure
the dryer has its own gas supply opened.
3. Test all connections by brushing on an approved noncorrosive
leak-detection solution. Bubbles will show a leak. Correct any
leaks found.