4" (102 mm) Diameter Exhaust Hoods
Box Hood Louvered Hood Angled Hood
Vent Hoods
DRYER VENTING REQUIREMENTS
Exhausthoodmustbeatleast12"(305mm)fromtheground
or any object that may be in the path of the exhaust (such as
owers,rocks,bushes,orsnow).
Maximum Vent Length/Vent Connection
Maximum length of vent system depends upon the type of vent
used, number of elbows, and type of exhaust hood.
Vent System Chart (Rigid Metal Vent)
No. of Box and Angled
90˚ Turns Louvered Hood Hood
0 64 ft. (19.5 m) 58 ft. (17.7 m)
1 54 ft. (16.5 m) 48 ft. (14.6 m)
2 44 ft. (13.4 m) 38 ft. (11.6 m)
3 35 ft. (10.7 m) 29 ft. (8.8 m)
4 27 ft. (8.2 m) 21 ft. (6.4 m)
Forventsystemsnotcoveredbytheventspecicationchart,
see your parts distributor.
Provision must be made for enough air for combustion and
ventilation. (Check governing codes and ordinances.) See
“Recessed Area and Closet Installation Instructions” in the
“Location Requirements” sections.
A4"(102mm)outlethoodispreferred.However,a2
1
2
"
(64 mm) outlet exhaust hood may be used. A 2
1
2
"(64mm)
outlet creates greater back pressure than other hood types.
For permanent installation, a stationary vent system is required.
Connect Vent
1. If connecting to existing vent, make sure the vent is clean.
2.Usinga4"(102mm)clamp,connectventtoexhaustoutlet
in dryer.
NOTE: Do not remove vent collar.
Vent System Length
3. Tighten hose clamp with Phillips screwdriver.
4. Make sure the vent is secured to exhaust hood with a
4"(102mm)clamp.
5.Movedryerintonalposition.Donotcrushorkinkvent.
Make sure dryer is level.
NOTE: Testing for proper ventilation should be done with a
Manometer.Minimum:0.01"(0.2mm).Maximum:0.6"(16mm).
12" min.
(305 mm)
Vent Collar