6. Locate blue float valve on/off lever. Move lever up about half way to shut water off.
7. Locate drain plug and pull the drain plug out to drain the reservoir and evaporator. When draining is
complete, return the plug to its original position.
8. Mix a solution of cleaner with water: 1.25 ounces of cleaner with 16 oz of warm water.
Care and Cleaning (con’t)
Note: Take care not to spill any scale remover on any nearby surface. Immediately wipe any spill with baking
soda and water.
9. Fill the 16 oz squirt bottle with the diluted scale remover.
10. Fill the reservoir with the scale remover solution using squirt bottle or other container. That will be about 8
ounces or half a squirt bottle.
WARNING
Ice machine scale remover contains
acids. Acids can cause burns.
If concentrated cleaner comes in
contact with skin, flush with water. if
swallowed, DO NOT induce vomiting.
Give large amounts of water or milk.
Call Physician immediately. Keep out
of the reach of children.
ON/OFF
ICE
MAKING
CHECK
WATER
TIME TO
CLEAN
CLEAN
RESET
11. Press and HOLD both the Clean-Reset and On/Off buttons for 5 seconds. The Time to Clean light will blink
on and off.
ON/OFF
ICE
MAKING
CHECK
WATER
TIME TO
CLEAN
CLEAN
RESET
PRESS
BOTH
12. The auger motor alone will be operating for 10 minutes, after that the compressor will start and in about 5-
8 minutes the machine will start to make ice. The Time to Clean light will now glow steady until the clean
cycle is complete.