Care and Cleaning
How to remove scale from the ice making system.
Cleaning this machine involves adding a solution of scale remover and water to the ice machine and continuing to add
it as it makes ice. The scale remover must be diluted to the correct ratio. A squirt bottle will make adding the scale
remover much easier when the unit is built in. If not built in, remove the top panel for reservoir access.
Recommended tools: Rubber gloves, squirt bottle & scale remover.
.
1. Scoop out and discard all of the ice.
2. Press and release the On/Off button.
CAUTION
DO NOT dent the fins.
Condenser cleaning
The condenser is like the radiator on a car, it has fins and tubes that can become clogged with dirt and lint.
To clean:
1. Remove the kickplate and front service panel.
2. Locate the condenser surface.
3. Vacuum the surface, removing all dust and lint.
4. Return the kickplate and front service panel to
their original positions. Fasten them to the
cabinet using the original screws.
Condenser
surface
Condenser
surface
Winterizing
1. Clean the ice making system.
2. Open the door and push and release the On/Off switch to turn the machine off.
3. Turn off the water supply.
4. Remove the back wall of the ice storage bin.
5. Remove the drain plug and drain water reservoir. Return plug to its original position.
6. Drain pump models should have about 1/2 gallon of RV antifreeze (propylene glycol) poured into the ice storage bin
drain.
Note: Automotive antifreeze must NOT be used.
7. Switch off and unplug the machine.
ON/OFF
ICE
MAKING
CHECK
WATER
TIME TO
CLEAN
CLEAN
RESET