6. Unscrew the metal cover and unscrew the blue regulator
cap. Keep the washer in place.
A
B
A
C
A. Metal cover
B. Washer
C. Blue regulator cap
7. Flip the blue regulator cap over and screw it back into
the metal cover.
A
B
8. Screw the metal cover securely back into place.
Do not overtighten.
To Convert Surface Burners (Natural Gas to LP Gas)
1. If installed, remove the burner grates.
2. Remove the burner caps.
3. Remove the burner base.
D
A
B
C
A. Natural gas position
B. LP gas position
A. Igniter electrode
B. Burner cap
C. Gas tube opening
D. Burner base
4. Apply masking tape to the end of a
9
32" (7 mm) nut driver
to help hold the gas orice spud in the nut driver while
changing it. Press nut driver down onto the gas orice spud
and remove by turning it counterclockwise and lifting out.
Set gas orice spud aside.
A
B
C
D
A. Igniter electrode
B. Orifice spud
C. Orifice spud holder
D. Screws
5. Remove the orice spuds shipped in the literature package
in the oven. Gas orice spuds are stamped with a number,
marked with 1 or 2 color dots, and have a groove in the hex
area. Replace the Natural gas orice spud with the correct
LP gas orice spud.
A
A. LP groove
Refer to the following chart for correct LP gas orice spud
ratings and to spud holder card for proper placement.
LP Gas Orifice Spud Chart for Surface Burners
Burner
Rating/Type Color Size (mm)
ID
Number Placement
15,000 BTU/
Stacked*
Silver
Black/
Orange
1.05
0.32
L105
L32
LF
14,200
BTU/ Ultra/
Stacked*
Silver 1.05 L105 LF/RF
8,000 BTU/
Semi
Red/
Orange
0.85 L85 RR/CTR
5,000 BTU/
Auxi
Red/
Blue
0.65 L65 LR
1,200 BTU/
Stacked/
Simmer*
Black/
Orange
0.32 L32 LF (Simmer)
*Not in all kits/models.
NOTE: Refer to the model/serial/rating plate located on the
oven frame behind the top right-hand side of the oven door
for proper sizing of spuds for each burner location.
6. Place Natural gas orice spuds in the orice spud bag.
IMPORTANT: Keep the Natural gas orice spuds in case
of reinstallation with Natural gas.
7. Replace the burner base.
8. Replace burner cap.
9. Repeat steps 1 to 7 for the remaining burners.
Complete Installation (Natural Gas to LP Gas)
1. Refer to the “Make Gas Connection” section for proper
connection of the range to the gas supply.
2. Refer to the “Electronic Ignition System” section for proper
burner ignition and operation.
3. Refer to the “Adjust Flame Height” section for burner ame
adjustments.
IMPORTANT: You may have to adjust the low setting for
each cooktop burner.
Checking for proper cooktop burner ame is very important.
Natural gas ames do not have yellow tips.
4. Refer to “Complete Installation” in the “Installation
Instructions” section of this manual to complete this
procedure.
IMPORTANT: Make sure to save the orifices that have
just been replaced in the conversion.