Loading ...
Loading ...
Loading ...
22
GAS CONVERSIONS
Gas conversions from Natural gas to LP gas or from LP gas
to Natural gas must be done by a qualied installer.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
LP Gas Conversion
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Turn manual shut-off valve to the closed position.
A
B
C
A. To range
B. Shut-off valve (closed position)
C. Gas supply line
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator
(Natural Gas to LP Gas)
1. Move the range out from the wall.
2. Locate the gas pressure regulator at the lower right corner
on the back of the range.
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
3. Remove the front lower panel of the range.
4. Disconnect the blower motor electrical connections.
5. Disconnect the downdraft blower bellows from the range.
Loading ...
Loading ...