30 49-60792 Rev. 3
REINSTALLING THE
REFRIGERATOR DOORS
Reverse steps 1 through 4 to reinstall refrigerator
doors, follow details below for critical alignments.
A
Reinstall center hinge first
and torque the screws to 65
in-lbs (7.34 N-m). With the LH
door at 90º to the front of the
case, lower the refrigerator
door onto the center hinge.
Ensure that the door and hinge align correctly.
B
Rotate doors closed and make sure moveable
center sealing portion of the door aligns with the
VWULNHU,IWKHGRRUZLOOQRWVHOIFORVHDIWHU
reinstalling, remove door, turn door upside down,
FKHFNDOLJQPHQWPDUNDQGDUURZWKHUHLVDQ
DOLJQPHQWPDUNRQWKHGRRUFORVXUHPHFKDQLVP,W
corresponds to an alignment arrow on the plastic
ring. Rotate door closure mechanism to align mark
DQGDUURZUHLQVWDOOGRRU'RRULQ'RRUPRGHOVGR
not have the same closure mechanism on the right
hand door. You may notice a difference in closure.
Securely tape the door shut with masking tape or
have a second person support the door. Reinstall
the top hinge and torque the screws to 65 in-lbs
(7.34 N-m).
C
Be sure to reinstall the ground wire and strain
relief to the top hinge.
'
Reinstall hinge cover. NOTE: Ensure wires are not
pinched or under screw bosses before tightening
screws.
3
REMOVE THE REFRIGERATOR
DOORS (cont)
Note: For proper installation later, please follow
the next step carefully.
)
Remove the tape and keeping the door as
straight as possible, open the door to 90º then lift
straight up to remove it.
REMOVE OPPOSITE DOOR
)ROORZWKHVDPHSURFHGXUHRQWKHRSSRVLWHGRRU
There are no water lines on the opposite side.
For Door in Door Models: Securely tape the
inner and outer doors before installing or removing.
90º door alignment not required during installation
or removal for these models.
4
REMOVE CENTER HINGE (if necessary)
5HPRYHWKHƎVFUHZVVHFXULQJWKHFHQWHUKLQJH
to the cabinet.
8VH7GULYHUWRUHPRYHRXWERDUGVFUHZ
5
Remove
center screw
Lift up & off
center hinge
2SHQ'RRUWR
Align flats with tab.
8QGHUVLGHRI
)UHVK)RRG'RRU
If door cannot be installed at 90° follow steps below:
,QVWDOOGRRUDWWRFDVHIURQW
,IVSDFHOLPLWVRSHQLQJGRRUWROHVVWKDQWKHQ
D5HPRYHGRRUFDUHIXOO\WXUQGRRUXSVLGHGRZQ
E&KHFNDOLJQPHQWRIGRRUFORVXUHPHFKDQLVPVKDIW
on underside of door. The flats on the shaft should
correspond to alignment tab on plastic ring or
mark on bottom end cap.
F,IVKDIWLVQRWDOLJQHGWRWDEPDUNXVLQJ´
Allen wrench, rotate door closure mechanism
shaft counterclockwise for right door and clock-
ZLVHIRUOHIWGRRU7KHQDOLJQIODWZLWKWDEPDUN
G,QVWDOOWKHGRRUDW
Loosen outer
screws
Installation Instructions
INSTALLING THE REFRIGERATOR (Cont.)
INSTALLATION INSTRUCTIONS