BATTERY CHARGING (SEALED BATTERY)
Always verify battery condition before and 1-2 hours after the end of charging.
STATE OF CHARGE VOLTAGE ACTION
CHARGE TIME
(USING CONSTANT
CURRENT
CHARGER @
STANDARD AMPS
SPECIFIED ON TOP
OF BATTERY)
100% 12.8-13.0 volts None, check at 3 mos.
from date of
manufacture
None required
75%-100% 12.5-12.8 volts May need slight
charge, if no charge
given, check in 3
months
3-6 hours
50%-75% 12.0-12.5 volts Needs charge 5-11 hours
25%-50% 11.5-12.0 volts Needs charge At least 13 hours,
verify state of charge
0%-25% 11.5 volts or less Needs charge with
desulfating charger
At least 20 hours
CAMBER AND CASTER
The camber and caster are non-adjustable.
FRONT/REAR SHOCK COMPRESSION
The compression damping clicker knob is located on the top of the front shock
reservoir and on the bottom of the rear shock reservoir. When the knob is turned
clockwise until it stops, the damping is in the fully closed position.
FOX SHOCKS
SETTING COMPRESSION DAMPING
Softest 20 clicks from closed
Factory
10 clicks from closed
Firmest 2 clicks from closed
1. Turn the clicker clockwise to increase compression damping.
2. Turn the clicker counter-clockwise to decrease compression damping.
100