En-10
Installation place
Avoid installing the air conditioner in the following places.
Where there is much machine oil.
Salty places such as the seaside.
Where sulde gas is generated such as a hot spring.
Where oil is splashed or where the area is lled with oily smoke (such as cook
-
ing
areas and factories, in which the properties of plastic could be changed
and damaged).
Where there is high-frequency or wireless equipment.
Where the air from the outdoor unit air outlet is blocked.
Where the operation sound or air from the outdoor unit does not bother the
house next door.
Electrical work
Provide an exclusive circuit for the power supply of the air conditioner.
Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
INSTALLATION PLACE AND
ELECTRICAL WORk
SPECIFICATIONS
To prevent the effects
of a uorescent lamp,
keep
as far apart as
possible.
wall, etc.
Inverter-type
uorescent lamp
K
eep a space to
prevent the pic-
ture
distortion or
the noise.
1 m
or
more
Radio
100
mm or
more
Well-
ventilated
dry
place
500
mm or
more
T
V
Cordless
phone or
Portable
phone
3 m or
more
1 m
or more
The installation location of the outdoor unit should
be at least 3 m away from the antennas for TV sets,
radios, etc. In areas where the reception is weak,
provide greater space between the outdoor unit and
the antenna of the affected device if operation of the air
conditioner interferes with radio or TV reception.
1
Set to the highest temperature in manual COOL mode,
and operate for 3 to 4 hours. Page 4
This dries the inside of the unit.
Moisture in the air conditioner contributes to growth of fungi, such as
mold.
2
Press to stop the operation.
3
Turn off the breaker and/or disconnect the power sup-
ply plug.
4
Remove all batteries from the remote controller.
When using the air conditioner again:
1
Clean the air lter. Page 8
2
Check that the air inlet and outlet of the indoor and
outdoor units are not blocked.
3
Check that the earth is connected correctly.
4
Refer to the “PREPARATION BEFORE OPERATION”,
and follow the instructions. Page 3
WHEN THE AIR CONDITIONER IS NOT
GOING TO BE USED FOR A LONG TIME
Indoor Outdoor
Cooling
Upper
limit
32°C DB
23°C WB
46°C DB
Lower
limit
21°C DB
15°C WB
-10°C DB
Heating
Upper
limit
27°C DB
24°C DB
18°C WB
Lower
limit
20°C DB
-15°C DB
-16°C WB
Guaranteed operating range
DB : Dry Bulb
WB : Wet Bulb
JG79A789H01_en.indd 10 2013/07/18 11:12:52