Beurer IPL 5800 PURE SKIN PRO

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Specification
  • Data sheet IPL 5800 Pure Skin Pro English EN - (English) Download
Other Documents
  • Instruction for use IPL 5800 Pure Skin Pro German DE, English EN, French FR, Italian IT, Spanish ES, Danish DA, Finnish FI, Dutch NL, Norwegian NO, Polish PL, Russian RU, Swedish SV, Turkish TR - (English) Download
  • Instruction for use IPL 5800 Pure Skin Pro English EN - (English) Download
IPL 5800 PURE SKIN PRO photo

Instruction for use IPL 5800 Pure Skin Pro English EN

This is the main product document for model IPL 5800 PURE SKIN PRO. Additionally, the document applies to other Beurer models: 4211125575007, 57500

The file format is pdf, 20 pages, you can download this manual here .

background
EN
Pure Skin Pro hair removal system
Instructions for use
IPL 5800
Pure Skin Pro
background
2
ENGLISH
Read these instructions for use carefully and
keep them for later use, be sure to make them
accessible to other users and observe the infor-
mation they contain.
WARNING
The device and adapter are only intended for use in
the home/private use and are not intended for com-
mercial use.
The device is only suitable for adults over the age of 18.
Children must not play with the device.
Check that the device and the mains cable are in per-
fect working order before each usage. In the event of
damage, the device must not be used.
The device and adapter must not get wet.
Do not use the device in damp environments, for ex-
ample near bathtubs, wash basins, showers or other
containers with water or other liquids– risk of electric
shock!
Never look into the light.
Do not insert any objects into the device.
Make sure that the devices vents are not covered.
In order to avoid an electric shock, do not touch any
internal components if the device is damaged.
If the mains connection cable of this device is dam-
aged, it must be disposed of. If it cannot be removed,
the device must be disposed of.
background
3
Never operate the device unsupervised. Children
should be supervised to ensure that they do not use
the device as a toy.
Under no circumstances should you open or repair
the device yourself, as faultless functionality can no
longer be guaranteed thereafter. Failure to adhere to
this instruction will void the warranty.
Table of contents
1. Included in delivery ......................................................................................... 4
2. Signs and symbols .......................................................................................... 4
3. Intended
use ........................................................................................... 5
4. Warnings and safety notes ........................................................................... 6
5. Device description ........................................................................................ 11
6. Initial
use ............................................................................................... 11
7. Usage ............................................................................................................... 13
7.1 Application methods .................................................................................. 14
7.2 Special instructions for facial treatments ................................................... 15
7.3 Application cycle ........................................................................................ 16
7.4 After treatment using the device ................................................................ 16
8. Cleaning and maintenance ......................................................................... 17
9. What if there are problems? ....................................................................... 17
10. Disposal ......................................................................................................... 17
11. Technical specifications ............................................................................ 18
12. Warranty/service ......................................................................................... 19
background
4
1. Included in delivery
Check that the device packaging has not been tampered with and make sure that all con-
tents are present. Before use, ensure that there is no visible damage to the device or ac-
cessories and that all packaging material has been removed. If you have any doubts, do
not use the device and contact your retailer or the specified Customer Services address.
1 x Pure Skin Pro hair remover
1 x Set of instructions for use
1 x Mains adapter
2. Signs and symbols
The following symbols are used in these instructions for use, on the packaging and on the
type plate for the device:
WARNING
Warning instruction indicating a risk of injury or damage to health
IMPORTANT
Safety note indicating possible damage to the unit/accessory
Note
Note on important information
DANGER
This device must not be used near to water or in water itself (e.g. in
a wash basin, or in the shower or bathtub) – risk of electric shock!
Observe the instructions for use
The unit is double-protected and thus corresponds to protection
class 2.
Only use indoors
Protect from moisture
Caution: optical radiation
Keep away from eyes!
Do not use on tanned skin or after exposure to the sun.
background
5
Disposal in accordance with the Directive on waste electrical and
electronic equipment (WEEE).
CE labelling
This product satisfies the requirements of the applicable European
and national directives.
The products demonstrably meet the requirements of the Technical
Regulations of the EAEU.
Separate the packaging elements and dispose of them in
accordance with local regulations.
Separate the product and packaging elements and dispose of
them in accordance with local regulations.
B
A
Marking to identify the packaging material.
A = material abbreviation, B = material number:
1-7 = plastics, 20-22 = paper and cardboard
Storage / Transport
Permissible storage and transport temperature and humidity
Polarity of d.c. power connector
Energy eciency class 6.
Direct current
The device is suitable for use with direct current only
Manufacturer
3. Intended
use
The IPL Pure Skin Pro device is intended for the removal of unwanted body hair in both
women and men.
The device must only be used on the legs, armpits, bikini line, chest, stomach, back and
face below the cheekbones (only suitable for facial use by women).
The device may only be used for the purpose for which it is designed and in the manner
specified in the instructions for use. Any improper use can be dangerous. The manufacturer
is not liable for damage resulting from improper or careless use.
background
6
IPL technology – how it works
The IPL Pure Skin Pro is a light-based device for lasting hair removal for private use. The
light-based hair removal process is a well-known and proven method. In 15 years of clinical
applications around the world, it has proven to be a safe and eective method for achiev-
ing lasting hair reduction.
How does the light remove the hair?
Light-based hair removal is founded on the principle of selective photothermolysis, which
uses optical energy to deactivate hair growth. To achieve such a thermal eect, the hair root
must selectively absorb the light energy and convert it into heat.
This selectivity is achieved when the optical energy that is released into the tissue is mainly
absorbed by the melanin pigment in the hair. The high-energy light is converted into thermal
energy (heat), which ultimately deactivates hair growth.
What eect does the hair growth cycle have on light-based hair removal?
Every hair on our body goes through the three phases of the hair growth
cycle: anagen, catagen and telogen. Only hairs that are in the anagen phase,
or growth phase, respond to treatment with IPL.
Although the duration of a complete hair growth cycle diers from person
to person and depends on the area of the body the hair is growing on, the
cycle generally lasts 18 to 24 months.
Please note that at least one complete hair
growth cycle is required in order to achieve
permanent hair removal using the beurer IPL
Pure Skin Pro.
4. Warnings and safety notes
WARNING
Before using the device, read the safety notes carefully and follow the instructions exactly
whenever using the device. Non-observance of the following instructions can result in in-
jury or material damage. Store the instructions for use for future reference and make them
accessible to other users.
This device may be used by persons with limited physical, sensory or mental capabilities,
provided they are supervised by a responsible person or they receive detailed instructions
on how to use the device.
Do not use the device when pregnant or breastfeeding.
Do not allow children to play with the device.
Anagen – growth
phase
Catagen – transiti
-
onal phase
Telogen – resting
phase
18–24
months
Anagen
Telogen
Catagen
background
7
If you discover extreme reddening, blistering or burns on the skin, stop using the device
immediately!
Never look directly into the light emitted from the IPL lamp.
Never attempt to release a light pulse into the air!
On the basis of the “Hair and skin colour chart” on the back page of these instructions for
use, determine which light intensities are best suited to the colour of your skin and your
body hair and whether this method is suitable for you to use at all (if not, this is marked
by an ’x’ in the chart).
Do not use the device on naturally dark skin.
Do not attempt to open or repair the device. If the device is opened, you could come into
contact with dangerous electrical components or with pulsed light energy, which could re
-
sult in serious injury and/or permanent damage to the eyes.
Do not use the device with a contact gel – this may damage the device.
Note
The device works best on dark hair types or on hair with a high melanin content. Black and
dark brown hair shows the best response and, although brown and light brown hair will also
respond to the treatment, it usually requires more hair removal sessions. Red hair could pro-
duce a reaction. White, grey or blond hair does not usually respond to the device, although
some users have noticed results after multiple hair removal sessions.
DANGER
Keep the device and adapter away from water! The IPL Pure Skin Pro is an electri-
cal device. Do not place it in water or allow it to fall into water or any other liquid.
This can lead to severe electric shock.
Do not use the device when taking a bath.
Do not use the device when it is damp or wet.
Do not reach for the device if it has fallen into water.
Immediately unplug the mains adapter if it has fallen into water.
Never touch the mains adapter or the device with wet hands!
WARNING
Do not use the device under any circumstances if you suer from one of the following
ailments:
If you suer from skin cancer or have done in the past, or if you have had potential ma-
lignancies on the skin areas to be treated.
If you suer from epilepsy with flash sensitivity.
If you suer from collagen disorders, including the formation of keloids or poor tissue repair.
If you suer from herpes or psoriasis in the treatment area, unless you have consulted a
doctor and received preventative treatment.
If you are photosensitive or suer from another form of light sensitivity, such as porphyria,
polymorphic photodermatosis, solar urticaria, lupus, etc.
If you suer from a metabolic disorder, such as diabetes.
If you suer from a blood clotting disorder.
background
8
Do not use the device under any circumstances if you are taking any of the following
medication:
If you are taking medication that makes the skin more sensitive to light, including
non-steroidal anti-inflammatory drugs (for example, aspirin, ibuprofen, paracetamol),
tetracyclines, phenothiazines, thiazide diuretics, sulphonylurea, sulfonamide, DTIC,
fluorouracil, vinblastine, griseofulvin, alpha hydroxy acids (AHAs), beta hydroxy acids
(BHAs), Retin-A
®
, Accutane
®
and/or topical retinoids.
If you are undergoing or recently underwent treatment with azelaic acid.
If you have been on a course of steroids in the past three months.
If you have had a skin exfoliation treatment or other skin smoothing procedure in the last
six to eight weeks.
If you have undergone radiation or chemotherapy in the past three months.
Do not use the device under any circumstances in the following areas:
On mucous membranes in the nose or throat area.
On or next to an active implant, such as a pacemaker or a device for incontinence, insu-
lin pump, etc.
On the face above the cheekbones, around the eyes, eyebrows or eyelashes,
as this could result in severe damage to the eyes.
On nipples, areolae, inner labia, vagina, anus, nose and ears.
Men must never use the device on the scrotum or face.
On piercings or other metal objects, such as earrings or jewellery.
On tattoos or permanent make-up in the area to be treated.
On dark brown or black patches, such as large freckles, birthmarks, moles, blisters or
warts.
On eczema, psoriasis, lesions, open wounds or acute infections. Wait until the aected
area has healed before using the device.
On damaged or cracked skin or in areas at risk of malignancy.
On an area of your body where you may like to have hair in the future.
This list is not exhaustive.
If you take prescription medicine, are monitored regularly due to an illness and/or are
unsure whether the device is safe for you to use, consult your doctor or dermatolo-
gist before using the device.
Possible side eects:
If the device is used in accordance with these instructions for use, side eects and compli-
cations rarely occur in relation to the use of the device.
After treatment, it is possible that the skin will be slightly red, itchy or warm to the touch.
These reactions are harmless and will quickly wear o.
For a short time, you may experience a skin reaction similar to sunburn on the treated area.
If this reaction does not wear o within three days, consult a doctor.
background
9
Dry or irritated skin may occur as a result of shaving or a combination of shaving and light
therapy. This reaction is harmless and will wear o within a few days. If you wish, you can
cool the aected area with some ice or a damp cloth.
If the skin continues to be too dry, you can apply an unscented moisturising cream 24
hours after treatment.
In rare cases, the treated skin can become very red and swollen. This is usually because
the intensity level you selected was too high and is more likely to occur in sensitive parts
of the body. Reddening and swelling should subside within two to seven days and should
be treated by frequent application of ice. Gentle cleaning is OK, but you should avoid
exposure to the sun.
Discolouration of the skin is very rare and appears as darker or lighter patches on the af-
fected skin area. It can be caused by using an intensity level that is too high for your skin
tone. If the discolouration does not subside within two weeks, consult a doctor. Do not
treat the discoloured areas again until the discolouration has fully disappeared.
In very rare cases, burns or lesions to the skin can occur after the treatment. The burn or le-
sion may take a few weeks to heal and, in extremely rare cases, you may be left with a scar.
In very rare cases, skin infections and inflammations may occur. These may be caused
through use of the device on wounds or cuts caused by shaving, or existing wounds or
ingrown hairs.
Severe pain may occur during or after treatment in the following cases: if you use the de-
vice on unshaven skin; if you select an intensity level that is too high for your skin tone; if
you treat the same skin area several times with light pulses; if you use the device on open
wounds, inflammations, tattoos, burns, etc.
In very rare cases, permanent scarring may occur. Scarring usually occurs in the form of a
flat, white lesion on the skin. Subsequent aesthetic treatment may be required to improve
the appearance of the scar.
In very rare cases, using the device can result in a blue/purple haematoma that may last
five to ten days. Once the haematoma fades, rusty brown discolouration of the skin (hy-
perpigmentation) can occur, which may be permanent.
Warning to sunbathers before and after treatment!
Sunbathing before treatment
1. After sunbathing, wait at least 2 weeks before using the device.
2. Before treatment, check the skin for signs of sunburn. If you have sunburn
that has not healed, wait until it has completely healed to use the device.
3.
Carry out a skin sensitivity test on the tanned skin to determine which energy intensity
is right for you.
Sunbathing after treatment
1. After treatment, wait at least 48 hours before sunbathing. Skin that is still reddened must
be kept out of the sun.
2.
For the first two weeks after the treatment, the treated skin must be covered with clothing
or sunblock (at least SPF 30) when you are out in the sun.
background
10
Tanning with artificial light
The instructions for “sunbathing before treatment” and “sunbathing after
treatment” also apply to tanning using an artificial light and tanning lotion.
Do not use the device 24 hours before or after using a sauna/swimming pool, as the
chlorine may lead to skin irritation.
IMPORTANT
To prevent damage
Do not attempt to open or repair your device. Attempting to open the device may damage
it and invalidates your warranty.
The device should never be left unattended when it is plugged into a socket.
Do not operate the device if the device itself, a cable or a plug is damaged and keep the
mains cable away from hot surfaces.
Always unplug the device from the mains immediately after use.
Do not use the device with attachments or accessories that are not recommended by
beurer GmbH.
During use, do not expose the device to temperatures below 10 °C or above 35 °C.
Do not use the device if you see or smell smoke during use.
Do not use the device if the fan opening on the device is cracked, is becoming detached
or is missing entirely.
Do not use the device if the skin colour sensor on the device or the light area is cracked
or broken.
Do not direct the light pulse at any other surfaces other than the skin. Otherwise, this may
result in serious damage to the light emission window or the skin colour sensor. Damage
may also be caused to the flashed surface. Only activate the light pulse once the device
is in contact with the skin.
After use, store the device in its original box.
Do not expose the device to several hours of direct sunlight or UV light in order to pre-
vent damage.
background
11
5. Device description
1
2
3
4
5
6
7
1. Light area 5. Indicator lamp
2. Skin colour sensor/skin contact sensor 6. Trigger button
3. Intensity display (3 levels) 7. Socket for device plug
4. ON/OFF/power selection button
Safety features
The device has a skin colour sensor. This skin colour sensor prevents you from treating
your skin if it is too dark or too tanned.
The
device also has a built-in UV filter that blocks harmful UV rays.
The device has a built-in skin contact sensor to protect the eyes. The sensor was devel-
oped so that no light pulses can be emitted when the device is held in the air. A light pulse
is only emitted when the skin contact sensor is in full contact with the skin.
6. Initial
use
Before you can start the application, you must first complete the following:
1. Using the hair and skin colour chart (on the back page of these instructions for use),
check which intensity level is suitable for you. An “x” in the table indicates that the
device is not suitable for you to use.
2. Before each application, shave the body parts that you wish to
treat. Donot use a hair removal cream instead of a razor.
background
12
3.
Ensure that the skin areas to be treated are shaved, dry and clean
(free from any residue such as powder, cream, make-up or deo-
dorant).
WARNING
Do not clean the skin with flammable liquids such as alcohol or acetone shortly before us-
ing the device.
4.
Clean the light area and skin contact sensor using a dry, lint-
free cloth.
5. Perform a skin sensitivity test on every body part that you would like to treat 48 hours
prior to the full treatment.
Carrying out the skin sensitivity test
1. Insert the device plug into the device and insert the mains plug into the mains socket.
The indicator lamp begins to flash green (stand-by).
2. Press the ON/OFF/power selection button. On the intensity display, a small light (le-
vel 1) begins to illuminate continuously in green.
Note
In the case of facial treatment, the skin sensitivity test should be performed on an area
without hair, for example below the ear or on the side of the neck.
3. Position the light area on the skin and press the trigger button in order
to release a light pulse at level 1. Ensure that the light area and skin contact sensor
come into full contact with the skin. A light pulse can only be released once the skin
contact sensor is in full contact with the skin. You will see a bright flash, hear a cracking
noise and may feel a slight burning sensation and/or warmth. The device fan switches
on after the first flash. Within 1-3 seconds (depending on the intensity level), the de-
vice is ready for the next pulse and the indicator lamp on the device is continuously
illuminated green.
4.
Position the skin contact sensor on another treatment area. Increase the intensity level
by pressing the ON/OFF/power selection button again and release a light pulse using
the trigger button. Do not exceed the maximum permitted/recommended intensity for
your skin tone (see the hair and skin colour chart on the back page of these instruc-
tions for use).
background
13
Note
Only increase the energy level if the previous level is not uncomfortable for you. If energy
level 1 is uncomfortable for you, do not increase the energy level.
5. If you experience an uncomfortable feeling after the flash, reduce the intensity.
6. Complete the skin sensitivity test. Wait 48 hours and examine the treated skin area.
If the treated skin surface appears normal (no reaction or only slight reddening), you
can treat the tested skin areas at the intensity level set for the skin sensitivity test.
Note
If your treated skin surface produces a reaction (e.g. reddening or swelling), wait until the
symptoms have fully subsided and then carry out another skin sensitivity test at a lower
intensity. If the treated skin surface reacts again, consult your doctor.
7. Usa ge
1. Insert the device plug into the device and insert the mains plug
into the mains socket. The indicator lamp begins to flash green
(stand-by).
2. Press the ON/OFF/power selection button. On the intensity
display, a small light (level 1) begins to illuminate continuously
in green.
3. If you wish to carry out an application at a higher intensity level,
increase the intensity by repeatedly pressing the ON/OFF/power
selection button until you have reached the desired intensity.
4. Position the light area on the skin and press the trigger button
in order to release a light pulse. Ensure that the light area and
skin contact sensor come into full contact with the skin. A light
pulse can only be released once the skin contact sensor is
in full contact with the skin. You will see a bright flash, hear a
cracking noise and may feel a slight burning sensation and/or
warmth. The device fan switches on after the first flash. Within
1-3 seconds (depending on the intensity level), the device is
ready for the next pulse and the indicator lamp on the device is
continuously illuminated green.
background
14
7.1 Application methods
WARNING
Do not treat the same area twice within one treatment. The risk of side eects is increased
if an area is treated more than once.
Note
The pulses from the device should be applied in rows – beginning at one end of each row,
continuing to the other end. This technique allows better monitoring of the areas of skin that
have already been treated and helps you to avoid treating the same area more than once
or treating overlapping areas of skin. The light area of the device is designed in such a way
that it leaves a temporary impression on the treated area of skin. These visible impressions
can be used for precise placement of the next pulse.
Application method 1 “Auto Flash” mode:
Hold down the trigger button. The device emits a series of consecutive light pulses so long
as the skin contact sensor is in full contact with the skin. After the third light pulse, which
is triggered by holding down the trigger button, the device automatically switches to “Auto
Flash” mode. The device automatically emits light pulses at regular intervals. This mode
does not require the trigger button to be pressed manually. The “Auto Flash” mode is suit-
able for treating large areas in particular, for example the legs.
Application method 2 “releasing individual flashes”:
Release the trigger button after each light pulse. For the next light pulse, position the device
on the area directly next to the area that has just been treated. Ensure that the light area
and skin contact sensor come into full contact with the skin. This mode guarantees precise
treatment, e.g. for knees or ankles.
Note
If the device does not emit any light pulses and the indicator lamp is orange, this indicates
that there is not enough contact between the skin sensor and the skin.
If the device does not emit any light pulses and the indicator lamp is red, this indicates that
the skin surface to be treated is too dark.
Note
Allow the device to cool for a few minutes if it seems too hot for you. You can continue your
treatment as normal after a short cooling period.
background
15
7.2 Special instructions for facial treatments
WARNING
Men must not use this device on the face.
Do not use the device on the face at an energy level higher than 2. Do not use the device
on the face above the cheekbones or on the eyes, eyebrows or eyelashes, as this could
result in severe damage to the eyes. Do not use the device on mucous membranes in
the nose or throat area.
The skin on your face is very sensitive and requires special care. Observe all warning and
safety notes in these instructions for use to prevent adverse consequences. We recom-
mend that you first perform a treatment on your body and get to know the device before
performing facial treatment. The device can be used to treat all areas of the face below
the cheekbones, such as the upper lip, cheeks, jaw, chin and neck.
1. You must carry out a skin sensitivity test 48 hours before treatment. The skin sensitivity
test should be performed on an area without hair, such as below the ear or on the side of
the neck, to determine the suitable energy level.
WARNING
Do not treat the tested area until at least one week after performing the skin sensitivity test.
2. Mark the treated area with a white eyeliner pencil. Use the marking as an orientation line
for issuing the pulses. This way you can prevent overlapping the treatment areas or treat-
ing other areas of the face by mistake.
3. Use a mirror to position the device correctly on the treatment area.
4.
Follow the instructions for use and observe the following specific instructions in particular.
Treating the upper lip
Position the light area of the device as shown in the figure. Trigger a pulse in
every marked zone.
Avoid applying the treatment to the nostrils and lips, as these areas are more
sensitive.
Note
You can “fold in” your lips or press them together to make the treatment area more taut, or
apply a thick layer of white eyeliner to the lips and around the edge of the lips. The white
line ensures that the energy of the flash is reflected and does not reach your lips, should
you accidentally apply a pulse to your lip.
Treating the cheeks and jaw
Position the light area of the device as shown in the figure. At each point,
trigger a pulse and move from one side of the cheek or jaw to the other.
background
16
Treating the neck and chin
Position the light area of the device as shown in the figure. At each point,
trigger a pulse and move from one side of the neck or chin to the other.
Care after facial treatment
Apply a soothing lotion such as aloe vera.
Do not use exfoliators, whitening lotions or similar products for at least
24hours, as this could irritate the treated skin.
For at least 48 hours after the treatment, avoid more than 15 minutes of direct exposure
to the sun. If the treated skin is exposed to sunlight during this period, sun protection with
SPF30 or higher must be applied.
Do not remove hair on the treated areas using wax or tweezers.
Remember that it may take a complete hair growth cycle for hair removal to be
complete.
7.3 Application cycle
For body treatment:
The first three or four hair removal sessions using the beurer Pure Skin Pro System should
be performed around two weeks apart.
The fifth to seventh hair removal sessions using the beurer Pure Skin Pro System should
be performed around four weeks apart. Afterwards, you may use the beurer Pure Skin Pro
System from time to time as necessary, until lasting results are achieved.
For facial treatment:
The first six hair removal sessions using the beurer Pure Skin Pro System should be per-
formed around two weeks apart.
The seventh to twelfth hair removal sessions using the beurer Pure Skin Pro System should
be performed around four weeks apart. Afterwards, you may use the beurer Pure Skin Pro
System from time to time as necessary, until lasting results are achieved.
This corresponds to the recommended treatment plan that has proven to achieve the best
results. You can, however, create a dierent personal treatment plan and still achieve sat-
isfactory results.
7.4 After treatment using the device
1. When you have completed the hair removal session, hold and press the ON/OFF/power
selection button for 3 seconds. The device is in stand-by mode when the the small, green
indicator lamp flashes.
2. Remove the mains adapter from the mains socket.
3. After each hair removal session, it is recommended that you clean the device, in particu-
lar the light area.
4. After cleaning, it is recommended that you store the device in its original box and keep
it away from water.
5.
After treatments, do not use any antiperspirants/deodorants as these may cause skin
irritation.
background
17
8. Cleaning and maintenance
After each hair removal session it is recommended that you clean your device, paying par-
ticular attention to the light area.
When cleaning, do not use any solvents or other aggressive or abrasive cleaning
agents, as the surface may become damaged.
Never immerse the device or any of its parts in water!
1. Before cleaning, remove the mains adapter of the device from the socket.
2. Clean the housing of the device with a dry, clean cloth.
3.
Gently clean the light area and skin contact sensor using a slightly
damp, lint-free cloth.
9. What if there are problems?
“The device will not switch on”
Ensure that the mains cable is correctly connected to the device.
Ensure that the mains adapter is inserted into a wall socket.
“No light pulse is emitted when I press the trigger button”
Ensure that the device is in full contact with the skin and that the light area and skin con-
tact sensor are pressed onto the skin evenly and firmly. For your safety, the trigger but-
ton only activates a pulse if the skin contact sensor is completely covered by the skin.
If the indicator lamp on the device is illuminated red, this indicates that your skin colour,
as measured by the skin colour sensor, is too dark for safe application. Test the device
on another part of your body or contact Customer Services.
If the indicator lamp on the device is illuminated orange, this indicates that the contact
with the skin, as measured by the skin contact sensor, is insucient. Increase the level of
contact with the skin or contact Customer Services.
If the indicator lamp permanently lights up red, the maximum number of pulses has been
reached.
10. Disposal
For environmental reasons, do not dispose of the device in the household waste
at the end of its useful life. Dispose of the unit at a suitable local collection or recy-
cling point. Dispose of the device in accordance with EC Directive – WEEE (Waste
Electrical and Electronic Equipment). If you have any questions, please contact the
local authorities responsible for waste disposal.
background
18
11. Technical specifications
Type IPL 5800
Treatment surface 3.1 cm
2
Technology
IPL (Intense Pulsed Light – for use in the home)
Wavelength
475 – 1200 nm
Max. energy level
max. 5 joules/cm
2
Selectable energy levels
3
Speed 1 pulse at intervals of:
1 second at level 1
2 seconds at level 2
3 seconds at level 3
Max. pulses in light
600,000
Dimensions
16 x 6.5 x 5.5 cm
Weight
Approx. 180 g
Temperature
Operation 10 – 40 °C
Storage -10 – 70 °C
Relative humidity
Operation 30 – 70% relative humidity
Storage 0 – 90% at 55 °C (non-condensing)
Mains part
Model number YJS024Y-1201800
Input
100 – 240 V~ 50/60 Hz, 0.5 A
Output
12.0 V
1.8 A, 21.6 W
Protection class This device is double-insulated (class II)
Polarity
Average active
eciency
≥86.55 %
No-load power
consumption
≤0.08 W
Subject to technical changes
background
19
12. Warranty/service
Further information on the warranty and warranty conditions can be found in the warranty
leaflet supplied.
Subject to errors and changes
background
575.00_IPL5800_2022-03-23_05_IM1_BEU
Repeat treatment if required
2 Weeks 2 Weeks 4 Weeks2 Weeks 4 Weeks 4 Weeks
t
r
e
a
t
m
e
n
t
I
t
r
e
a
t
m
e
n
t
II
t
r
e
a
t
m
e
n
t
III
t
r
e
a
t
m
e
n
t
IV
t
r
e
a
t
m
e
n
t
V
t
r
e
a
t
m
e
n
t
VI
t
r
e
a
t
m
e
n
t
VII
Body
Repeat treatment if required
2 Weeks 2 Weeks 2 Weeks2 Weeks 2 Weeks 4 Weeks
t
r
e
a
t
m
e
n
t
I
t
r
e
a
t
m
e
n
t
II
t
r
e
a
t
m
e
n
t
III
t
r
e
a
t
m
e
n
t
IV
t
r
e
a
t
m
e
n
t
V
t
r
e
a
t
m
e
n
t
VI
t
r
e
a
t
m
e
n
t
VII
Face
Energy
1-2
Energy
1-2
Energy
1-2
Energy
1-2
Energy
1-2
Energy
1-2
Energy
1-2
Energy
1-2
Black
Dark
brown
Brown
Dark
blonde
Light
blonde
Red
head
Gray/
white
Skin
Type
Hair
Energy
2-3
Energy
2-3
Energy
2-3
Energy
2-3
I
Energy
2-3
Energy
2-3
Energy
2-3
Energy
2-3
II
Energy
2-3
Energy
2-3
Energy
2-3
Energy
2-3
Energy
1-2
Energy
1-2
Energy
2-3
Energy
2-3
Energy
2-3
Energy
1-2
Energy
1-2
Energy
2-3
Energy
2-3
Energy
2-3
III IV V
VI
E
N
* The energylevel should primarily be chosen based on your
own comfort.
** The higher the energylevel, the more efficient the treat-
ment will be.
Hair and skin colour chart
Beurer GmbH • Söflinger Str. 218 • 89077 Ulm, Germany • www.beurer.com
www.beurer-healthguide.com • www.gesundheitsratgeber.com

Specifications

Beurer IPL 5800 PURE SKIN PRO Questions and Answers

See other models: MP 41 MP 59 MP 48 MP 100 FW 20 COSY